Very Late Bioresorbable Scaffold Thrombosis Caused by Intraluminal Scaffold Dismantling
نویسندگان
چکیده
منابع مشابه
Bioresorbable Coronary Scaffold€Thrombosis
Fro Ka Ca Fra Ma Ab Eg fro ha res Pu Ma BACKGROUND Recent reports suggest an elevated incidence of bioresorbable vascular scaffold (BVS) thrombosis (scaffold thrombosis [ScT]). OBJECTIVES This study investigated occurrence rates, clinical and angiographic characteristics, and possible mechanisms of ScT in all-comer patients undergoing BVS implantation at 2 German and 2 Swiss hospitals. METHODS ...
متن کاملVery late bioresorbable scaffold thrombosis after discontinuation of dual antiplatelet therapy
Inflammation induced by pathogens or of autoimmune origin is particularly harmful to terminally differentiated organs with poor regenerative capacity, such as the heart and brain. Chronic inflammation is thought to impair heart failure, neurodegenerative diseases, and metabolic syndrome. Interestingly, increased resting heart rate has been linked to cognitivedecline after ischaemic stroke. This...
متن کاملVery late bioresorbable vascular scaffold thrombosis following discontinuation of antiplatelet therapy.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehu419 Online publish-ahead-o...
متن کاملVery Late Scaffold Thrombosis Due to Insufficient Strut Apposition.
A 46-year-old patient underwent implantation of a bioresorbable vascular scaffold (BVS) (Absorb 3.5 28 mm, Abbott Vascular, Abbott Park, Illinois) in April 2013 for a de-novo stenosis of the right coronary artery (Figures 1A to 1B). A total of 6 months after implantation, a follow-up angiography including optical coherence tomography (OCT) was performed, showing a partial malapposition of the s...
متن کاملVery late thrombosis observed on optical coherence tomography 22 months after the implantation of a polymer-based bioresorbable vascular scaffold.
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . doi:10.1093/eurheartj/ehv046 Online publish-ahead-o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Interventions
سال: 2016
ISSN: 1936-8798
DOI: 10.1016/j.jcin.2016.05.041