VIDAS D-dimer: fast quantitative ELISA for measuring D-dimer in plasma.

VIDAS D-dimer (bioMérieux) is a new quantitative ELISA for D-dimer determination designed for the VIDAS automated system. The test contains single-dose, ready-to-use reagents and is completed within 35 min. Quantitative results are obtained from a calibration curve stored in the software of the system and expressed as fibrinogen equivalent units. The two-step capture/tag test relies on two comp...

متن کامل

Weil's disease with elevated plasma D-dimer.

We report a case of Weil's disease manifesting elevation of plasma D-dimer in the acute phase. Later, in the convalescent phase after treatment, the plasma levels of D-dimer returned to normal. Plasma D-dimer can be used as a marker of fibrin formation and degradation. Based on our observations, we conjecture that fibrin formation and fibrinolysis may occur in the acute phase of Weil's disease.

متن کامل

Plasma Fibrinogen and D-dimer in Children With Sepsis: A Single-center Experience

Background & Objectives:  In sepsis, enhanced fibrin formation, impaired fibrin degradation, and intravascular fibrin deposition lead to a prothrombotic state. The current study aimed at measuring various coagulation parameters to predict an early marker for disseminated intravascular coagulation (DIC). Methods: The current prospective s...

متن کامل

D Dimer Assay

Introduction A new test for determination of circulating fibrin degradation products has recently been marketed in the U.S. Known genericaUy as the D-dimer assay, it is a direct latex agglutination assay employing monoclonal anubody specific for digestion products of crosslinked fibrin. It is offered as an alternative to or replacement for the widely available Thrombo-Wellcotest assay for fibri...

متن کامل

Comparing D-dimer assays

• Including many patients with elevated D-dimer concentrations due to other causes than VTE may give a false increase in sensitivity and negative predictive value • The prevalence of VTE has an influence on the predictive values – higher prevalence gives lower NPV • A high ratio of proximal to distal DVT will increase both the sensitivity and the negative predictive value • A study focused on P...