VMM - An ASIC for Micropattern Detectors
نویسندگان
چکیده
منابع مشابه
A Comparison of Micropattern Gas Avalanche Detectors
A large number of new micropattern detectors have emerged in the last few years, offering cheap and robust solutions for high luminosity tracking. A brief overview and comparison are presented. Invited Talk at the 6th International Conference on Advanced Technology and Particle Physics, Como, Italy Oct. 5-9, 1998 *Presently at CERN-EP, Geneva Switzerland e-mail [email protected]
متن کاملMicroPattern Gas Detectors with pixel read-out
MicroPattern Gas Detectors are position-sensitive proportional counters whose sense electrodes are constructed using microelectronics, thin-film or advanced PCB techniques. The feature size attainable using these methods is of the order of a few microns and the detectors show excellent spatial resolution and fast charge collection. The real challenge with this class of detectors is the design o...
متن کاملGaseous Micropattern Detectors In Astrophysics, Radiology And Plasma Physics
Multiwire gaseous detectors have matured in the last few decades with major implications in particle physics experiments, they have also been successfully refined for use in other fields: X-rays for medical imaging, UV and single photon detection, neutron and crystal diffraction studies etc. Their major limitation has been a modest rate capability (flux ~ 10/mm). In the last decade several micr...
متن کاملToward coherent neutrino detection using low-background micropattern gas detectors
The detection of low energy neutrinos ( few tens of MeV) via coherent nuclear scattering remains a holy grail of sorts in neutrino physics. This uncontroversial mode of interaction is expected to profit from a sizeable increase in cross section proportional to neutron number squared in the target nucleus, an advantageous feature in view of the small probability of interaction via all other chan...
متن کاملGaseous Micropattern Detectors: High- Energy Physics and Beyond
Multiwire gaseous detectors have matured in the last few decades with major implications in particle physics experiments. They have also been successfully refined for use in other fields: X-rays for medical imaging, UV and single photon detection, neutron and crystal diffraction studies, etc. Their major limitation has been a modest rate capability (10/mm). In the last decade, several micropatt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: EPJ Web of Conferences
سال: 2018
ISSN: 2100-014X
DOI: 10.1051/epjconf/201817407001