Voltage Sag Mitigation Effect Considering Failure Probability According to the Types of SFCL
نویسندگان
چکیده
The development of industrial technology is based on electronic devices that are sensitive to power quality. Thus, the demand for high-quality and reliable supplies increasing. Voltage sag results in severe problems manufacturing process quality-sensitive loads. When a fault occurs multi-ground distribution system, magnitudes current voltage faulted nonfaulted feeders become high. Hence, installing superconducting limiter (SFCL) an effective method compensating limitation sag. This study evaluates effects improving magnitude, duration, frequency according type SFCL used. First, system analyzed using PSCAD/EMTDC, simulation software, current-limiting element (CLE) SFCL. Second, expected caused by feeder assessed. Finally, improvement effect CLE compared. trigger-type with resistor as has been evaluated found be
منابع مشابه
Voltage Sag Mitigation by Network Reconfiguration
The electric power distribution system must be designed to operate and supply acceptable level of electrical energy to customers. Power utilities must ensure that the power supply to customers is with voltage magnitude within standard levels. Other features like minimal interruptions and minimal system power loss also must be considered. Hence, the quality and reliability of supply must be main...
متن کاملImplementation of Dynamic Voltage Restorer for Mitigation of Voltage Sag
Power quality is one of major concerns in the present. It has become important, especially with the introduction of sophisticated devices, whose performance is very sensitive to the quality of power supply. The dynamic voltage restorer (DVR) is one of the modern devices used in distribution systems to improve the power quality. In this paper, emergency control in distribution systems is discuss...
متن کاملMitigation of voltage sag/swell using Dynamic voltage restorer (DVR)
The most noticeable topic for electrical engineering is power quality in recent year. Power quality problem is an occurrence manifested as a nonstandard voltage, current or frequency. Utility distribution networks, sensitive industrial load and critical commercial operation suffer from various types of outages and service interruption can cost significant financial losses. One of the major prob...
متن کاملMitigation of Inrush Current of Transformer using Voltage Sag Compensator
In the power system voltage sag become the important issue for industries. According to the survey 92% of the interruptions at industrial installations are voltage sag related. In various companies voltage sag may affect many manufactures and introduce sufficient losses in the power system. The voltage sag compensator, based on a transformer coupled series connected voltage source inverter, is ...
متن کاملVoltage Sag Mitigation Using Distribution Static Compensator System
This paper presents the custom power devices to improve the power quality by using a Distribution Static Compensator (DSTATCOM). Custom power is a technology driven product and service solution which embraces a family devices such as DSTATCOM. It describes the techniques of correcting the supply voltage sag in a distribution system by DSTATCOM. The steady state performance of system with or wit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2023
ISSN: ['1996-1073']
DOI: https://doi.org/10.3390/en16020625