Voltammetric analysis of weak acids with microelectrodes
نویسندگان
چکیده
منابع مشابه
Voltammetric discrete current of polyaniline-coated latex particles at microelectrodes
Suspensions of polyaniline-coated latex particles 13 μm in diameter showed the integer-fold voltammetric currents at the microelectrode of which size was similar to the diameter of the particles. The currents did not vary with concentrations of polyaniline particles but varied accidentally with each voltammetric run. They were caused by the reduction of a few polyaniline particles adsorbed on t...
متن کاملVoltammetric Analysis of Pesticides
Pollution due to pesticides is a daily and growing problem, closely related to the intensification of agricultural activities devoted to the satisfaction of human needs in terms of food. In fact, throughout the world, pesticides are intensively used as defoliants or against weed and pests in a large variety of crops (Castanho et al., 2003; De Souza & Machado, 2005a). Also known as persistent or...
متن کاملIonization of Water, Weak Acids and Weak Bases
lthough many of the solvent properties of water can be explained in terms of the uncharged H2O molecules,the small degree of ionization of water to hydrogen ions (H) and hydroxide ions (OH ) must also be taken into account. Like all reversible reactions, the ionization of water can be described by an equilibrium constant. When weak acids or weak bases are dissolved in water, they can contribute...
متن کاملStudy of complexes of cadmium with some L-amino acids and vitamin-C by voltammetric technique
Voltammetric technique was used to study the binary and ternary complexes of cadmium with L-amino acids and vitamin-C (L-ascorbic acid) at pH =7.30 ± 0.01, μ = 1.0M KNO3 at 25oC and 35oC. Cd (II) formed 1:1:1, 1:1:2 and 1:2:1 complexes with L-lysine, L-ornithine, L-threonine, L-serine, L-phenylglycine, L-phenylalanine, L-glutamic acid and L-aspartic acid used as primary ligands and L-ascorbic a...
متن کاملDetermination of selected phenolic acids in beer extract by liquid chromatography with voltammetric-amperometric detection.
A voltammetric-amperometric detector for liquid chromatography based on a dual electrode electrochem-ical cell has been developed. This detector enables voltammograms to be obtained without the charging current problems inherent in single electrode voltammetric detectors. The detector is operated by scanning the potential of the upstream (voltammetric) electrode and detecting the electrolysis p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Electroanalytical Chemistry
سال: 2004
ISSN: 1572-6657
DOI: 10.1016/j.jelechem.2004.03.015