Voltammetric determination of capsaicin using CeO2-surfactant/SWNT-modified electrode
نویسندگان
چکیده
منابع مشابه
Voltammetric Determination of α-Lipoic Acid using Poly(Vanillin) Modified Platinum Electrode
In the present study electrochemical detection of α-lipoic acid (α-LA) was carried out with a poly(Vanillin) modified platinum electrode p(VA)/PtE in Brinton Robinson buffer (BR) solution. The platinum electrode surface’s was modified with cyclic voltammetry method. The prepared Pt electrode was characterized by cyclic voltammetry in ferrocyanide and scanning electron microscopy (SEM) images. T...
متن کاملAnodic Stripping Voltammetric Determination of Nitrite Using Carbon Paste Electrode Modified with Chitosan
A simple method for anodic stripping voltammetric determination of nitrite using carbon paste electrode modified with biomolecular chitosan, is described. In this method, the electrode is activated electrochemically by scanning 5 replicates over the potential range from +500 to +1400 mV immersing in 0.5 M HCl solution. Following this step, the nitrite sample containing 0.1 M KCl is pre-concentr...
متن کاملVoltammetric Determination of Prochlorperazine and Ethopropazine Using a Gold Electrode Modified with Decanethiol SAM
The voltammetric behavior of prochlorperazine and ethopropazine at a decanethiol (DEC) self-assembled monolayer (SAM) modified gold electrode (DEC/Au) has been studied. It was observed that prochlorperazine exhibited an anodic peak at about 0.60 V (vs SCE), while ethopropazine exhibited two anodic peaks at about 0.49 V and 0.58 V on DEC/Au in pH 10 sodium carbonate buffer. This was due to their...
متن کاملVoltammetric determination of tinidazole using a glassy carbon electrode modified with single-wall carbon nanotubes.
An electrochemical method based on a single-wall carbon nanotubes (SWNTs) film-coated glassy carbon electrode (GCE) was described for the determination of tinidazole. In a 0.1 M Britton-Robinson buffer with a pH of 10.0, tinidazole yields a very sensitive and well-defined reduction peak at -0.78 V (vs. SCE) on a SWNTs-modified GCE. Compared with that on a bare GCE, the reduction peak of tinidaz...
متن کاملVoltammetric Determination of Ferulic Acid Using Polypyrrole-Multiwalled Carbon Nanotubes Modified Electrode with Sample Application
A polypyrrole-multiwalled carbon nanotubes modified glassy carbon electrode-based sensor was devised for determination of ferulic acid (FA). The fabricated sensor was prepared electrochemically using cyclic voltammetry (CV) and characterized using CV and scanning electron microscope (SEM). The electrode shows an excellent electrochemical catalytic activity towards FA oxidation. Under optimal co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Arabian Journal of Chemistry
سال: 2020
ISSN: 1878-5352
DOI: 10.1016/j.arabjc.2017.12.019