Voltammetric Recognition of Ca2+
نویسندگان
چکیده
منابع مشابه
Voltammetric characteristics of miconazole and its cathodic stripping voltammetric determination.
Miconazole is reduced at mercury electrode above pH 6 involving organometallic compound formation, responsible for an anomalous polarographic behavior. The electrodic process presents a large contribution of the adsorption effects. The drug can be determined by cathodic stripping voltammetry from 8.0 x 10(-8) to 1, 5 x 10(-6) molL-1 in Britton-Robinson buffer pH 8.0, when pre-accumulated for 30...
متن کاملVoltammetric Analysis of Pesticides
Pollution due to pesticides is a daily and growing problem, closely related to the intensification of agricultural activities devoted to the satisfaction of human needs in terms of food. In fact, throughout the world, pesticides are intensively used as defoliants or against weed and pests in a large variety of crops (Castanho et al., 2003; De Souza & Machado, 2005a). Also known as persistent or...
متن کاملVoltammetric Determination of Fenitrothion
The adsorptive stripping differential pulse voltammetric method was proposed for the determination of fenitrothion [O,O-dimethyl O-(4-nitro-m-tolyl)phosphorothioate]. The voltammetric response was evaluated in 0,04 mol l-1 Britton-Robinson buffer with respect to the accumulation time and potential, and concentration dependence. The relationship between peak current and fenitrothion concentratio...
متن کاملDirect voltammetric specific recognition of dopamine using AlIII-DA complexes at the hanging mercury drop electrode.
In this paper, we firstly report the direct voltammetric recognition and determination of dopamine (DA) by using Al(III)-DA complexes at the hanging mercury drop electrode (HMDE). A new sensitive cathodic peak of Al(III)-DA can be detected at -900 mV (vs. SCE) in 0.1 M NH(4)Cl-NH(3).H(2)O-0.1 M KCl buffer solution at pH 8.5. This unique -900 mV cathodic peak arises from the specific interaction...
متن کاملVoltammetric Trace Determination of Lanthanum
Optimum conditions for the determination of lanthanum at sub μg level have been developed employing differential pulse polarography. A detection limit of 0.5μg/ml has been achieved. The method successfully been applied for analysis of lanthanum in industrial wastes.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the Korean Chemical Society
سال: 2010
ISSN: 0253-2964
DOI: 10.5012/bkcs.2010.31.11.3115