Volume contact constraints at arbitrary resolution
نویسندگان
چکیده
منابع مشابه
Accurate Interactive Animation of Deformable Models at Arbitrary Resolution
Providing realistic interactive simulation requires a powerful animation method with a highly detailed rendering. Based on continuum mechanics, the finite element method needs a volumetric representation of the object to animate. This paper proposes an automatic method for building meshes that are well adapted to interactive simulation starting from miscellaneous input data. Contrary to commonl...
متن کاملAnimating Shapes at Arbitrary Resolution with Non-Uniform Stiffness
We present a new method for physically animating deformable shapes using finite element models (FEM). Contrary to commonly used methods based on tetrahedra, our finite elements are the bounding voxels of a given shape at arbitrary resolution. This alleviates the complexities and limitations of tetrahedral volume meshing and results in regular, well-conditionned meshes. We show how to build the ...
متن کاملConstraints on qq̄γγ Contact Interactions at Future Hadron Colliders
We explore the capability of the Tevatron and LHC as well as other future hadron colliders to place limits on the possible existence of flavor-independent qq̄γγ contact interactions which can lead to an excess of high pt diphoton events with large invariant masses. Constraints on the corresponding eeγγ contact interaction already exist from LEP. In the case of hadron colliders, strong constraint...
متن کاملNear-Interpolation to Arbitrary Constraints
This paper is concerned with the computation of solutions to the problem of best near-interpolation by parametric curves to constraints of the form f(ti) ∈ Ki for general sets Ki, including derivative constraints when ti has multiplicity greater than one. The minimizers are spline curves that we represent as smoothing splines with weights that are determined from the Lagrange multipliers corres...
متن کاملInner volume BOLD-fMRI at ultra-high spatial resolution
Introduction: Multi-Echo FLASH imaging in combination with echo train shifting [1,2] offers BOLD sensitivity for matrix sizes up to 256 x 256 leading to in-plane resolutions of about 1 mm. Long measurement times and low Signal-to-Noise-Ratio (SNR) preclude BOLDfMRI going to higher resolutions. Hence, only a reduction in the Field-of-View (FOV) further increases spatial resolution. Latter, howev...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: ACM Transactions on Graphics
سال: 2010
ISSN: 0730-0301
DOI: 10.1145/1833351.1778819