Water-chemical mode calculation of npp block multistage circulating cooling systems
نویسندگان
چکیده
منابع مشابه
Diagnosis of Heat Exchanger Scales in Cooling Water Systems
An experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. To collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulat...
متن کاملInvestigating the Bio-corrosion Inhibition Effect of Enzymes in Circulating Cooling Water System
To avoid the secondary pollution that inorganic corrosion inhibitor may cause in circulating cooling water, the bio-corrosion inhibition effect of lysozyme, catalase, lipase, and laccase, as the biologic inhibitors without the above problem, and the increased bio-corrosion inhibition effect of Ca+2 and Mg+2 are studied. An enzyme with corrosion properties was selected by rotary coupon test. The...
متن کاملOptimal Design of Cooling Water Systems
Re-circulating cooling water systems are generally used to remove waste heat from hot process streams in conditions above the ambient temperature in many types of industries such as chemical and petrochemical, electric power generating stations, refrigeration and air conditioning plants, pulp and paper mills, and steel mills. Typical re-circulating cooling water systems are constituted by a mec...
متن کاملLinear-dendritic block copolymers as a green scale inhibitor for calcium carbonate in cooling water systems
Water-soluble monomer APEG-PG-(OH)n were produced and the Structure of APEG-PG-(OH)5 were identified by 1H-NMR. APEG-PG-(OH)n were copolymerized with maleic anhydride (MA) to synthesize no phosphate and nitrogen free calcium carbonate inhibitor MA/APEG-PG-(OH)n. The structure and thermal property of MA/APEG-PG-(OH)5 were characterized and measured by 1H-NMR, GPC and TGA. The observation shows t...
متن کاملdiagnosis of heat exchanger scales in cooling water systems
an experimental database is compiled in order to fingerprint the scales formed over the hot surfaces of heat exchangers, in cooling water systems or other systems with similar chemistry. to collect these data, a dynamic simulating pilot plant was designed with considerable application flexibility among which simultaneous flow of water with different velocity and heat fluxes to three simulating ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Technology audit and production reserves
سال: 2014
ISSN: 2312-8372,2226-3780
DOI: 10.15587/2312-8372.2014.25330