Wear of highly crosslinked polyethylene acetabular components
نویسندگان
چکیده
منابع مشابه
Wear of highly crosslinked polyethylene acetabular components
BACKGROUND AND PURPOSE Wear rates of highly crosslinked polyethylene (XLPE) acetabular components have varied considerably between different published studies. This variation is in part due to the different techniques used to measure wear and to the errors inherent in measuring the relatively low amounts of wear in XLPE bearings. We undertook a scoping review of studies that have examined the i...
متن کاملIn vivo wear of polyethylene acetabular components.
Polyethylene acetabular cups retrieved at revision surgery were measured by a shadowgraph technique to determine linear wear, and the values were compared with those obtained from radiographs. There was a close correlation between them, although the radiographic measurements slightly underestimated the true wear. Average linear wear rates for surface-replacement components were much greater tha...
متن کاملPolyethylene wear in uncemented acetabular components.
We measured polyethylene wear in 231 porous-coated uncemented acetabular cups. We divided the hips into two groups according to the fixation of the femoral component, by cementing (n = 97) or press-fit (n = 134). Follow-up was from three to five years. The patients in two sub-groups were matched for weight, diagnosis, sex, age and length of follow-up. The linear wear rate of cups articulated wi...
متن کاملPolyethylene wear from retrieved acetabular cups.
Laboratory wear testing of ultra high molecular weight polyethylene from 12 Charnley acetabular cups, removed after periods of up to 17.5 years showed that the large patient-to-patient variations in clinical penetration rate cannot be explained by batch-to-batch variation in the wear resistance of the material. Nor was there any evidence of a time-dependent degradation in wear resistance of the...
متن کاملIsolated polyethylene exchange versus acetabular revision for polyethylene wear.
UNLABELLED Polyethylene wear and osteolysis are not uncommon in THA mid- and long-term. In asymptomatic patients the dilemma faced by the orthopaedic surgeon is whether to revise the cup and risk damage to the supporting columns and even pelvic discontinuity or to perform isolated polyethylene exchange and risk a high rate of postoperative recurrent instability and dislocation that will necessi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Orthopaedica
سال: 2014
ISSN: 1745-3674,1745-3682
DOI: 10.3109/17453674.2014.972890