Wide-Area Detection of Voltage Instability From Synchronized Phasor Measurements. Part II: Simulation Results
نویسندگان
چکیده
منابع مشابه
Neuro-Fuzzy Based Algorithm for Online Dynamic Voltage Stability Status Prediction Using Wide-Area Phasor Measurements
In this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. This technique uses synchronized phasors measured by phasor measurement units (PMUs) in a wide-area measurement system. In order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...
متن کاملneuro-fuzzy based algorithm for online dynamic voltage stability status prediction using wide-area phasor measurements
in this paper, a novel neuro-fuzzy based method combined with a feature selection technique is proposed for online dynamic voltage stability status prediction of power system. this technique uses synchronized phasors measured by phasor measurement units (pmus) in a wide-area measurement system. in order to minimize the number of neuro-fuzzy inputs, training time and complication of neuro-fuzzy ...
متن کاملVoltage Coordination via Communication in Large-Scale Multi-Area Power Systems. Part II: Simulation Results
This two-part paper deals with the coordination of the control actions in a network of many interacting components, where each component is controlled by independent control agents. As a case study we consider voltage control in large electric power systems where ever-increasing pressures from the liberalization and globalization of the electricity market has led to partitioning the power syste...
متن کاملSynchronized Phasor Measurements in a Dual Layer Hybrid State Estimator
Original scientific paper The architecture of the proposed Dual Layer Hybrid State Estimator starts with the linear state estimator that only takes synchrophasors as inputs and calculates states of the buses with the deployed Phasor Measurement Units (PMUs) and their adjacent buses. These states are used to obtain the pseudomeasurements that are processed together with conventional SCADA measur...
متن کاملWide-Area Adaptive Load Shedding Control to Counteract Voltage Instability
A two-level adaptive load shedding scheme against voltage instability is proposed, adjusting its actions to the severity of the situation. The lower level includes a set of distributed controllers which curtail loads once the voltages at monitored transmission buses fall and stay for some time below threshold values. The adaptive nature of the proposed scheme comes from the upper level adjustin...