Wideband linear detector arrays for optoacoustic imaging based on polyvinylidene difluoride films

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Efficient Wideband Linear Arrays For Imaging And Therapy

transducer t o achieve a large intensity gain and deep penetration [1,2]. The fixed focused single element is mechanically moved in three dimensions to treat a volume. or akernatively in two dimensions snch as with annular arrays 13.41. IrnagiKq or monitoring performance with such transducers hay been limited due to their narrow bandwidt,h. low frequency, and/or need for mechanical scanning. M...

متن کامل

Nano-Scale Characterization of a Piezoelectric Polymer (Polyvinylidene Difluoride, PVDF)

The polymer polyvinylidene difluoride (PVDF) has unique piezoelectric properties favorable for Micro-Electro-Mechanical Systems (MEMS) and Nano-Electro-Mechanical Systems (NEMS) applications. In the present research, we conducted nanometer-length scale characterization of this material using several high-resolution techniques. Specifically, we used an atomic force microscope (AFM) to study the ...

متن کامل

Micron-Sized Pored Membranes Based on Polyvinylidene Difluoride Hexafluoropropylene Prepared by Phase Inversion Techniques

In this study, micron-sized pored membranes, based on the co-polymer polyvinylidene difluoride hexafluoropropylene (PVdF-HFP) were prepared via phase inversion techniques. The aim of the approach was to find less harmful and less toxic solvents to fabricate such films. Therefore, the Hansen solubility approach was used to identify safer and less toxic organic solvents for the phase inversion pr...

متن کامل

Simple Method for Detecting Glycoproteins Dot-blotted or Electro-blotted on to a Polyvinylidene Difluoride Membrane.

A simple method is described for detecting glycoproteins which had been dot-blotted or electro-blotted on to a polyvinylidene difluoride (PVDF) membrane after sodium dodecyl sulfate (SDS)-polyacrylamide gel electrophoresis. This method is based on the periodate oxidation of glycoproteins on a PVDF membrane with subsequent staining by the chromophoric hydrazide, 4-N,N-dimethylamino-4'-azobenzene...

متن کامل

Wideband optical detector of ultrasound for medical imaging applications.

Optical sensors of ultrasound are a promising alternative to piezoelectric techniques, as has been recently demonstrated in the field of optoacoustic imaging. In medical applications, one of the major limitations of optical sensing technology is its susceptibility to environmental conditions, e.g. changes in pressure and temperature, which may saturate the detection. Additionally, the clinical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of Biomedical Optics

سال: 2018

ISSN: 1083-3668

DOI: 10.1117/1.jbo.23.9.091408