Pulsed Wire Magnetic Field Measurements on Undulator U10p
T.C. Fan*, F.Y. Lin, C.S. Hwang, Ian C. Hsu Synchrotron Radiation Research Center, Hsinchu, Taiwan National Tsing Hua University, Hsinchu, Taiwan Abstract Several laboratories have used the pulsed wire method for magnetic field measurement. The acoustic wave distortion of the wire was observed. The limitations of this method were discussed. A pulsed wire system is under test in SRRC on an undul...
متن کاملField Measurements of the Kek B-factory Dipole and Wiggler Magnets
The KEK B-Factory (KEKB) [1] consists of 3.5 GeV positron (LER) and 8.0 GeV electron (HER) rings and has more than 290 dipole and 150 wiggler magnets. Both the LER and the HER use four types of dipole magnets. Wiggler magnets are used for the LER. Three long flipflop coil systems were used to measure the transverse distribution of the integrated magnetic field along the beam direction. Each dip...
متن کاملPulsed-magnetic-field measurements of the composite-fermion effective mass.
Magnetotransport measurements of Composite Fermions (CF) are reported in 50 T pulsed magnetic fields. The CF effective mass is found to increase approximately linearly with the effective field B * , in agreement with our earlier work at lower fields. For a B * of 14 T it reaches 1.6m e , over 20 times the band edge electron mass. Data from all fractions are unified by the single parameter B * f...
متن کاملViscosity Measurements of Liquid Toluene at Low Temperatures Using a Dual Vibrating-Wire Technique
1 Centro de Química Estrutural, Instituto Superior Técnico, Universidade Técnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisbon, Portugal. 2 Universidade Aberta, Rua da Escola Politécnica, 147, 1269-001 Lisbon, Portugal. 3 Academia Militar, Paço da Rainha, 29, 1150-244 Lisbon, Portugal. 4 To whom correspondence should be addressed. E-mail: [email protected] 5 University of Southampton, Highf...
متن کاملSubtyping of Salmonella enterica isolated from humans and food animals using Pulsed-Field Gel Electrophoresis
Salmonella infections are the second leading cause of zoonotic bacterial foodborne illness. Main source of infection in human is contaminated food products. The aim of this study was sub typing isolates of Salmonella entericaobtained during our previous study byPulsed Field Gel Electrophoresis (PFGE) technique. All 46 Salmonella isolates were serotyped and then subjected to PFGE. Total isolates...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1992
ISSN: 0168-9002