X-ray diffraction study of cold-worked α-AgCd alloys
نویسندگان
چکیده
منابع مشابه
High-pressure X-ray diffraction study on α-PbF2
The high-pressure behaviour of α-PbF2 has been investigated by angular-dispersive synchrotron X-ray powder diffraction up to 6.55(8) GPa. The fit of a 3-order BirchMurnaghan equation-of-state gave the volume at zero pressure V0=194.14(4) Å 3 and the bulk modulus b0=47.0(6) GPa with the pressure derivative b’=7.9(4). The continuous-symmetry-measure approach has been used for the quantification o...
متن کاملX-ray diffraction studies of oxidized high-palladium alloys.
OBJECTIVE The purpose of this study was to use x-ray diffraction (XRD) to obtain new information about the oxide layers on four representative oxidized high-palladium alloys. METHODS Cast specimens of two Pd-Cu-Ga alloys and two Pd-Ga alloys, with both polished and etched surfaces and air-abraded surfaces, were subjected to oxidation procedures recommended by the manufacturers. The specimens ...
متن کاملDetection of breast cancer using non-invasive X-ray diffraction technique of hair: A preliminary study
Background: An early diagnosis of breast cancer relates directly to an accurate treatment plan and strategy. Early detection of breast cancer before its development would be a significant reduction of morbidity and mortality rates. The aim of this preliminary study is to investigate the sensitivity of Wide Angle X-ray diffraction (WAXRD) method on women hair samples of healthy and breast cancer...
متن کاملX-Ray Diffraction Study of Amorphous CeFe2H3 and GdFe2H3 Alloys Produced by Hydrogenation
für Naturforschung in cooperation with the Max Planck Society for the Advancement of Science under a Creative Commons Attribution 4.0 International License. Dieses Werk wurde im Jahr 2013 vom Verlag Zeitschrift für Naturforschung in Zusammenarbeit mit der Max-Planck-Gesellschaft zur Förderung der Wissenschaften e.V. digitalisiert und unter folgender Lizenz veröffentlicht: Creative Commons Namen...
متن کاملX-ray diffraction study of Anodisc filters.
X-ray diffraction from Anodisc membrane filters is measured and analyzed. The patterns are consistent with pores of constant diameter and a Gaussian distribution of pore-pore spacing. The mean distance between pores, measured using x rays is 0.37 microm compared to 0.32 microm calculated from the nominal density of pores/cm(2). The results may be modeled both in terms of the convolution of a st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Acta Crystallographica
سال: 1966
ISSN: 0365-110X
DOI: 10.1107/s0365110x66001889