X-ray diffraction tomography employing an annular beam
نویسندگان
چکیده
منابع مشابه
Energy-dispersive X-ray diffraction using an annular beam.
We demonstrate material phase identification by measuring polychromatic diffraction spots from samples at least 20 mm in diameter and up to 10 mm thick with an energy resolving point detector. Within our method an annular X-ray beam in the form of a conical shell is incident with its symmetry axis normal to an extended polycrystalline sample. The detector is configured to receive diffracted flu...
متن کاملX-ray absorption tomography employing a conical shell beam.
We demonstrate depth-resolved absorption imaging by scanning an object through a conical shell of X-rays. We measure ring shaped projections and apply tomosynthesis to extract optical sections at different axial focal plane positions. Three-dimensional objects have been imaged to validate our theoretical treatment. The novel principle of our method is scalable with respect to both scan size and...
متن کاملInterlaced X-ray diffraction computed tomography
An X-ray diffraction computed tomography data-collection strategy that allows, post experiment, a choice between temporal and spatial resolution is reported. This strategy enables time-resolved studies on comparatively short timescales, or alternatively allows for improved spatial resolution if the system under study, or components within it, appear to be unchanging. The application of the meth...
متن کاملIntroducing an Optimized Method for Obtaining X-ray Diffraction Patterns of Biological Tissues
Introduction Individual X-Ray diffraction patterns of biological tissues are obtained via interference of coherent scattering with their electrons. Many scientists have distinguished normal and cancerous breast tissue, bone density, and urinary stone types using the X-Ray diffraction patterns resulting from coherent scattering. The goal of this study was to introduce an optimized method for obt...
متن کاملNon-destructive X-ray Diffraction Tomography with Cone-Beam CT Systems
In this paper we describe a novel approach for introducing true material selectivity as a fourth dimension into cone-beam CT (CBCT) imaging by integrating means for energy-dispersive X-ray diffraction (EDXRD) measurements into the system. In order to minimize the acquisition time for the diffraction data, a compressed sensing reconstruction scheme requiring only a dilute set of projections was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Optics Express
سال: 2014
ISSN: 1094-4087
DOI: 10.1364/oe.22.011930