effect of different instrumentation techniques on vertical root fracture resistance of endodontically treated teeth

نویسندگان

saeid tavanafar dept. of restorative dentistry, ajman university of science and technology, ajman, united arab emirates.

azadeh karimpour department of restorative dentistry, ajman university of science and technology, ajman, united arab emirates

hamideh karimpour dept. of restorative dentistry, ajman university of science and technology, ajman, united arab emirates.

abdulrahman mohammed saleh dept. of restorative dentistry, ajman university of science and technology, ajman, united arab emirates.

چکیده

statement of the problem: vertical root fractures are catastrophic events that often result in tooth extraction. many contributing factor are associated with increasing incidence of vertical root fracture. root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture. purpose: the aim of this study was to compare the effects of three different instrumentation techniques on vertical root fracture resistance of endodontically treated teeth. materials and methods: in this study, 120 freshly extracted mandibular premolar teeth of similar dimensions were decoronated and randomly divided into control (n=30), nickel-titanium hand k-file (hf, n=30), biorace rotary file (br, n=30), and waveone reciprocating single-file (wo, n=30) groups. after cleaning and shaping the root canals, ah26 was used as canal sealer, and obturation was completed using the continuous wave technique. the root canals were embedded vertically in standardised autopolymerising acrylic resin blocks, and subjected to a vertical load to cause vertical root fracture. the forces required to induce fractures were measured using a universal testing machine. anova and tukey’s post-hoc test were used to analyse the data. results: all experimental groups showed statistically significant reductions in fracture resistance as compared with the control group. there was a statistically significant difference between the hf and br groups. the wo group did not differ significantly from the hf group or the br group. conclusion: all three instrumentation techniques caused weakening of the structure of the roots, and rendered them susceptible to fracture under lesser load than unprepared roots. the fracture resistance of roots prepared with the single-file reciprocating technique was similar to that of those prepared with niti hand and rotary instrumentation techniques.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Different Instrumentation Techniques on Vertical Root Fracture Resistance of Endodontically Treated Teeth

STATEMENT OF THE PROBLEM Vertical root fractures are catastrophic events that often result in tooth extraction. Many contributing factor are associated with increasing incidence of vertical root fracture. Root canal preparation is one of the predisposing factors which can increase the root susceptibility to vertical fracture. PURPOSE The aim of this study was to compare the effects of three d...

متن کامل

Comparing Fracture Resistance of Endodontically Treated Teeth Using Different Preparation-Obturation Combinations

Background:One of the main reasons for extraction of endodontically treated teeth is vertical root fracture (VRF). Some factors such as root canal treatment are involved in vertical root fracture because of their potential to weaken the tooth structure. Therefore, this study aimed to investigate the effect of combining different obturation materials and rotary systems on the fr...

متن کامل

Effect of root morphology on the susceptibility of endodontically treated teeth to vertical root fracture: An ex-vivo model.

Vertical root fracture (VRF) of endodontically treated teeth is relatively common, and the involved teeth have a poor prognosis. Previous destructive methodologies applied force to the root in an uneven manner; thus, the associated experiments could not truly assess the mechanical behavior of VRF. This problem was resolved in the current study via the novel application of a bursting pressure me...

متن کامل

Effect of Different Luting Cements on Fracture Resistance in Endodontically Treated Teeth

INTRODUCTION The aim of the present study was to evaluate the effect of three types of luting cements used for post cementation on the fracture resistance of endodontically treated maxillary premolars, restored with resin composite. MATERIALS AND METHODS One hundred intact single-rooted human maxillary premolars were randomly divided into 5 groups of 20 each. In groups 2-5, post spaces were p...

متن کامل

The effect of different root canal sealers on the fracture resistance of endodontically treated teeth-in vitro study

Background The aim of this study was to compare the in vitro effects of four different root canal sealers on the fracture resistance of endodontically treated teeth. Materials and Methods Seventy-five freshly extracted human mandibular premolars were used for the study. Teeth were divided into five groups based on type of root canal sealers used. Gutta-percha was used for all the samples: Gro...

متن کامل

In Vitro Evaluation of the Effect of Tooth Structure Loss on Fracture Resistance of Endodontically Treated Teeth

Introduction: Since preserving the structure of treated teeth is a critical success factor, studying the effects of tooth structure loss on fracture resistance of the tooth tissue appears necessary. The aim of this study was to evaluate the consequences of the loss of different tissues regarding fracture resistance of teeth undergoing root canal treatment without the use of indirect restoration...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, shiraz university of medical sciences

جلد ۱۶، شماره ۰۴، صفحات ۵۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023