effect of contact time between silicone impression materials and stone on dimensional stability of resultant cast

نویسندگان

bijan heidari department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

fariborz vafaei department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

alireza izadi department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

amir saleh department of prosthodontics, school of dentistry, hamadan university of medical sciences, hamadan, ir iranسازمان اصلی تایید شده: دانشگاه علوم پزشکی همدان (hamadan university of medical sciences)

چکیده

background numerous factors have an effect on the accuracy of an impression and resultant cast, and these include: impression material, impression technique, tray selection, impression disinfection, storage time of impression before pouring, stone type used for fabrication of cast. up to now, there has been little research conducted on the effect of contact time of a cast with an impression, on the dimensional stability of a cast. objectives the purpose of this study was to evaluate the effect of the contact time of silicone impression materials with stone casts, on the dimensional stability of resultant casts. materials and methods a total of 44 impressions were made from a stainless steel master model, with each one of two silicone impression materials (elite hd+ and speedex), and poured with elite master type iv. the thickness of the light-body material (1 mm) was provided by using four copings. the resulting casts from each material were placed in four groups(n = 11) after each contact time with the impression (1 hour, 24 hours, 48 hours, 1 week). distance between anterior and posterior abutments was measured for the casts and master model. data were analyzed by two-way analysis of variance and a tukey test. results the relationship between the dimensional stability of the casts and the simultaneous effect of the impression material and contact time of the cast with the impression was not statistically significant (p = 0.099). type of impression material on the dimensional stability of the cast had no significant effect (p = 0.163). increased contact time of the cast with the impression resulted in increased dimensional change (p < 0.001). conclusions dimensional stability of the casts after different contact time with the impression was acceptable. the best time to separate the cast from the impression was one hour after pouring the impression.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Autoclave Sterilisation on the Dimensional Stability and Tear Strength of Three Silicone Impression Materials

Objectives: There is a risk of spreading infectious material via non-sterile impressions. The aim of this study was to compare the effect of autoclave sterilisation on dimensional stability and tear strength of impression materials. Methods: Twenty-four specimens were produced using a standard ruled test block for each of three impression materials (Affinis, Aquasil and Speedex) to test dimensi...

متن کامل

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil)

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil) Dr. M. Sabouhi* - Dr. M. Dakhilalian** - Dr. N. Nehchiri*** *- Assistant Professor of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Member of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Scienc...

متن کامل

Comparative Analysis of Dimensional Accuracy of Two Types of Silicone Impression Materials: Optosil and Elite-HD

Statement of the Problem: Understanding about impression materials, their properties, uses and manipulation can guide operators towards having more successful restorations. Purpose: The aim of this in vitro study was to compare the accuracy of a condensation silicone impression material, Optosil, and an addition poly siloxane impression material, Elite-HD. Materials and Method: A laboratory mod...

متن کامل

the effect of disinfection with sodium hypochlorite 0.5% on dimensional stability of condensation silicone impression materials of speedex and irasil

statement of the problem: impression materials are concerned as a significant source of cross-contamination because of exposure to blood and saliva. purpose: considering the importance of infection control in the dental environments, this study is performed to investigate the dimensional changes of two condensation silicone impression materials, speedex and irasil, after immersion in 0.5% sodiu...

متن کامل

the effect of esp materials on medical studentsreading proficiency

چکیده این تحقیق " مواد درسی " را به عنوان یکی از بحث برانگیزترین موضوعات آموزش زبان تلقی کرده و درتلاش است به سه سوال عمده پاسخ دهد: 1) آیا بکارگیری جزوات گرداوری شده توسط گروهی از مدرسین تاثیر بسزایی در میزان توانش خواندن و درک متون انگلیسی دانشجویان پزشکی دارد؟ 2) آیا استفاده از مواد درسی اصلی( بین المللی )، توانش خواندن و درک متون انگلیسی دانشجویان پزشکی را به طور چشمگیری تحت تاثیر قرار م...

15 صفحه اول

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
avicenna journal of dental research

جلد ۵، شماره ۱، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023