comparison of vessel sealing systems with conventional

نویسندگان

kemal peker erzincan university department of general surgery, erzincan, turkey; mengücek gazi eğitim ve araştırma hastanesi genel cerrahi, turkey. tel: +90-5359368528, fax: +90-4462122216

abdullah i̇nal erzincan university department of general surgery, erzincan, turkey

huriye güllü erzincan university department of anesthesiology & reanimation, erzincan, turkey

düriye gül erzincan university department of anesthesiology & reanimation, erzincan, turkey

چکیده

background haemorrhoids are cushions of submucosal vascular tissue located in the anal canal starting just distal to the dentate line. haemorrhoidal disease is a common anorectal disorder which has symptoms of bleeding, prolapse, pain, thrombosis, mucus discharge, and pruritus. haemorrhoidectomy is one of most frequently performed anorectal operation worldwide. objectives the aim of this study was to compare the effectiveness of the ligasure tissue sealing device, harmonic scalpel and conventional mm open haemorrhoidectomy. materials and methods sixty-nine patients with newly diagnosed symptomatic grade three or grade four haemorrhoidal disease, from july 2011 to december 2011 were recruited for the study. patients were prospectively randomized to ligasure, harmonic scalpel and conventional haemorrhoidectomy. patients were evaluated on the basis of the mean operative time, postoperative pain, day of discharge, early and late complications. results each group has twenty-three patients. ten (14.5 %) were female and fifty-nine (85.5 %) were male. mean age were 44.5 ± 10.8 for ligasure group, 39.5±14.4 for harmonic scalpel group and 39.8 ± 13.6 for conventional haemorrhoidectomy group. mean operative time was 12.6 ± 2.9 for ligasure group, 12.6 ± 2.5 for harmonic scalpel group and 22.3 ± 4.5 for conventional haemorrhoidectomy group. postoperative pain and required analgesic dose were significantly lower for conventional haemorrhoidectomy. wound healing was also more rapid in conventional haemorrhoidectomy than both ligasure and harmonic scalpel. conclusions lateral heat dissipation of energy based cautery such as harmonel scalpel and ligasure is considerably high when compared with conventional methods. more thermal damage which is generated on tissue seems to be the reason for increased degree of postoperative pain and delay in wound healing.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Vessel Sealing Systems with Conventional

BACKGROUND Haemorrhoids are cushions of submucosal vascular tissue located in the anal canal starting just distal to the dentate line. Haemorrhoidal disease is a common anorectal disorder which has symptoms of bleeding, prolapse, pain, thrombosis, mucus discharge, and pruritus. Haemorrhoidectomy is one of most frequently performed anorectal operation worldwide. OBJECTIVES The aim of this stud...

متن کامل

Laparoscopic vessel sealing technologies.

Laparoscopic vessel sealing devices have revolutionized modern laparoscopy. These devices fall into 2 major categories: advanced bipolar and ultrasonic instruments. The range of tissue effects available with these technologies is more limited than with conventional monopolar electrosurgery; however, both advanced bipolar and ultrasonic devices efficiently seal vessels (≤7-mm and ≤5-mm diameter,...

متن کامل

Utility of vessel-sealing systems in thyroid surgery.

The LigaSure vessel-sealing system (VSS) represents a new approach to intraoperative ligation. This clinical study retrospectively examined the utility of the VSS in thyroid surgery. In this study, we analyzed 56 consecutive patients who underwent thyroid surgery. Characteristics such as operative duration, the volume of intraoperative hemorrhage, and postoperative course were analyzed and comp...

متن کامل

Study and Comparison of Seismic Behaviour of Isolator-Damper Hybrid Control System with Conventional Structural Systems

In this paper, in addition to introduce a hybrid structural system contained local isolators and dampers, its behavior and functional capabilities were studied on a conventional structure. For this purpose, an RC frame building with six-story was designed based on valid codes and then, in four cases based on the number of spans, it was split into two separate adjacent frames. Base isolation was...

متن کامل

Feasibility of using a vessel sealing system in a human pulmonary lobectomy: a retrospective comparison of this procedure with or without a vessel sealing system.

OBJECTIVE Despite recent advances in video-assisted thoracoscopic lobectomy, some technical limitations still remain. Our current study purpose was to determine if the vessel sealing system (VSS) has utility in this procedure. METHOD 112 patients who underwent an anatomic pulmonary lobectomy at our institute were evaluated retrospectively. The burst pressure of pulmonary vessels, which was di...

متن کامل

Thyroid surgery: use of the LigaSure Vessel Sealing System versus conventional knot tying.

BACKGROUND The aim of this work is to compare the use of conventional knot tying vs. LigaSuretrade mark Vessel Sealing System (Valley Lab, Boulder, CO) in patients undergoing thyroid surgery. We hypothesized that use of the LigaSure would reduce operating time while resulting in a similar rate of complications. METHODS This study was conducted in Endocrine Surgery Unit, Mansoura University Ho...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian red crescent medical journal

جلد ۱۵، شماره ۶، صفحات ۴۸۸-۴۹۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023