comparison of opening torque of grooved and non-grooved memory alloy screws for mandibular fracture fixation

نویسندگان

bijan movahhedian

shadab ghods

anahita azadi

mahdi kadkhodazadeh

چکیده

background and aims. the aim of this study was to assess the opening torque of grooved and non-grooved screws made of shape memory alloys (sma) for fixation of mandibular fractures. materials and methods. in this in vitro study the opening torques of ten sma screws with grooves and ten sma screws without grooves were compared in 20 holes (10 holes for grooved screws and 10 holes for non-grooved screws) placed in the bovine mandible. statistical significance was set at p < 0.05. results. the mean opening torque was 2.27 ± 0.43 nm for screws in the control group and 2.05 ± 0.45 nm for screws in the grooved group (p < 0.05, p = 0.08). conclusion. this study revealed that the torque needed for opening the grooved screws was higher in comparison with current fixation screws; however, the difference was not statistically significant

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Analysis of Helically Grooved and Circumferentially Grooved Labyrinth Seal

Labyrinth seals are used in turbo-machinery for reducing the leakage of working fluid. The energy lost by the fluid passing through the gap between labyrinth seal and rotor causes the reduction in leakage rate. But the fluid in between the labyrinth seal and rotor induce various forces (radial and tangential forces). These forces can be represented by certain numbers of coefficients, such as st...

متن کامل

Patterning flows using grooved surfaces.

Through a simple analytical description we quantify how pressure-driven flows over grooved surfaces develop transverse components, which, for shallow grooves, can be modeled with simple anisotropic effective boundary conditions. Helical recirculation results in channels or capillaries with grooved walls. An experimental validation of our model is presented. Our analysis provides a workable guid...

متن کامل

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

a comparison of linguistic and pragmatic knowledge: a case of iranian learners of english

در این تحقیق دانش زبانشناسی و کاربردشناسی زبان آموزان ایرانی در سطح بالای متوسط مقایسه شد. 50 دانش آموز با سابقه آموزشی مشابه از شش آموزشگاه زبان مختلف در دو آزمون دانش زبانشناسی و آزمون دانش گفتار شناسی زبان انگلیسی شرکت کردند که سوالات هر دو تست توسط محقق تهیه شده بود. همچنین در این تحقیق کارایی کتابهای آموزشی زبان در فراهم آوردن درون داد کافی برای زبان آموزان ایرانی به عنوان هدف جانبی تحقیق ...

15 صفحه اول

First Metatarsophalangeal Joint Arthrodesis: A Retrospective Comparison of Crossed-screws, Locking and Non-Locking Plate Fixation with Lag Screw

Background:Locking plate fixation is increasingly used for first metatarsophalangeal joint (MTP-I) arthrodesis. Still there is few comparable clinical data regarding this procedure. Methods:We retrospectively evaluated 60 patients who received an arthrodesis of the MTP-I between January 2008 and June 2010. With 20 patients each we performed a locking plate fixation with lag screw, arthrodesis w...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of periodontology and implant dentistry

جلد ۶، شماره ۲، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023