magnetic equipped wire device-for closed interlocking intramedullary femoral nailing: a method that avoids exposure to ionizing radiations

نویسندگان

mohammad hosein ebrahimzadeh orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran

hamid farzadfar orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran

hami ashraf department of research and education, razavi hospital, mashhad, ir iran

gholam reza khoshsima orthopedic research center, department of orthopedic surgery, mashhad university of medical sciences, mashhad, ir iran

چکیده

conclusions we found the magnetic field assistant device to be an accurate, radiation-independent jig for close passing of guide wire after close reduction of femoral fracture. it can reduce the need for radiation during placement of guide wire for closed intramedullary nailing of the long bones. more studies are required to improve and evaluate the technique and equipment. results outcomes of applying the new system on 15 fiberglass artificial femurs and 20 bovine femurs as well as 10 human cadaveric femurs were successful. materials and methods a stainless steel femoral intramedullary guide wire equipped with a small magnet on its end was designed; and also an exchange tube that would enter into the bone canal upon the guide wire to maintain the alignment. besides these mentioned parts, we applied the standard classic interamedullary nailing set. pin guide was inserted in the femoral intramedullary canal from periformis fossa. another equipped magnetic guide wire was inserted from distal portal which was created in the lateral epicondyle. two opposite magnetic poles supposed to find each other in the fracture site. after replacing the guide-wire with guide pine; the alignment would be checked by a c-arm. the study has been designed in 4 phases including moulage phase, animal phase on young cows, and a human cadaveric phase. the last step of the study is under design and it consists of a randomized controlled clinical trial on the elective patients. background intramedullary nailing is probably the best procedure for treating the long bone fractures in the lower limb. such operation is guided by fluoroscopy for the guide-wire insertion like fracture reduction and distal locking. radiation exposure during interlocked nailing continues a matter of challenge. objectives the aim of this experimental study was to design and test the new aiming device for closed intramedullary nailing and to reduce the radiation exposure and the operation time during the procedure.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

bed-assisted closed reduction intramedullary nailing for femoral shaft fracture

Objective: To compare treatment of femoral shaft fractures using traction bed assisted closed reduction (CR) or conventional open reduction (OR) for intramedullary nail fixation. Methods: The study group consisted of 126 patients with femoral shaft fractures who were treated via intramedullary nail fixation from July 2009 to May 2013. Traction bed assisted CR was adopted in 71 patients, while O...

متن کامل

Antegrade interlocking nailing for distal femoral fractures.

PURPOSE To assess outcomes of antegrade interlocking nailing for supracondylar or intercondylar fractures of the distal femur. METHODS Records of 10 women and 20 men aged 20 to 70 (mean, 48.7) years who underwent antegrade interlocking nailing for distal femoral fractures were reviewed. 23 patients had closed fractures and 7 had open fractures; 6 had associated fractures of the forearm or tib...

متن کامل

Intramedullary nailing for pathological femoral fractures.

PURPOSE To evaluate whether the operating time correlates with the survival and outcome in patients who underwent intramedullary nailing for metastatic femoral fractures. METHODS Records of 10 men and 11 women aged 43 to 86 (mean, 66) years who underwent intramedullary nailing (4 bilaterally) for metastatic femoral fractures between 1999 and 2003 were reviewed. The patients were followed up f...

متن کامل

Breakage of the radiopaque wire from the medullary tube during closed antegrade intramedullary nailing for femoral shaft fracture.

We report a complication of radiopaque wire breakage from the medullary tube during closed antegrade intramedullary nailing for a femoral shaft fracture. To avoid such complication, the medullary tube should be checked carefully for colour changes and surface defects, and tested for flexibility before each use. The medullary tube should also be replaced before 100 exposures to autoclaving.

متن کامل

Intraoperative Distal Femoral Fine Wire Traction to Facilitate Intramedullary Nailing of the Femur.

Many techniques have been employed to facilitate intramedullary nailing of femur fractures. Maintaining limb length during the operation can be difficult. The authors describe the use of distal femoral fine wire skeletal traction as a technique to maintain reduction while allowing intramedullary nailing of femur fractures. This technique is safe, is effective, and negates the need for a fractur...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
razavi international journal of medicine

جلد ۲، شماره ۳، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023