seismic demand evaluation of elevated reinforced concrete water tanks

نویسندگان

h. shakib jala-al-ahamad street, tehran, p.o.box:14115-143;

f. omidinasab jala-al-ahamad street, tehran, p.o.box:14115-143;

m.t. ahmadi jala-al-ahamad street, tehran, p.o.box:14115-143;

چکیده

elevated water tanks as one of the main lifeline elements are the structures of high importance. since they are extremely vulnerable under lateral forces, their serviceability performance during and after strong earthquakes is a matter of concern. as such, in recent years, the seismic behavior of water tanks has been the focus of a significant amount of studies. in the present work, three reinforced concrete elevated water tanks, with a capacity of 900 cubic meters and height of 25, 32 and 39 m were subjected to an ensemble of earthquake records. the behavior of concrete material was assumed to be nonlinear. seismic demand of the elevated water tanks for a wide range of structural characteristics was assessed. the obtained results revealed that scattering of responses in the mean minus standard deviation and mean plus standard deviation are approximately 60% to 70 %. moreover, simultaneous effects of mass increase and stiffness decrease of tank staging led to increase in the base shear, overturning moment, displacement and hydrodynamic pressure equal to 10 - 20 %, 13 - 32 %, 10 - 15 % and 8 - 9 %, respectively.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic Behavior Evaluation of Concrete Elevated Water Tanks

Elevated tanks are important structures in storing vital products, such as petroleum products for cities and industrial facilities, as well as water storage. These structures have various types and are constructed in a way that a greater portion of their weight is concentrated at an elevation much about the base. Damage to these structures during strong ground motions may lead to fire or other ...

متن کامل

Seismic Behavior Assessment of Concrete Elevated Water Tanks

Elevated tanks are very important structures and consist of various types. Water supply is vital to control fires during earthquakes. Also they are utilized to store different products, like petroleum supplies in cities and industrial zones. Damage to these structures during strong ground motions may lead to fire or other hazardous events. Elevated tanks should stay functional after and before ...

متن کامل

seismic behavior evaluation of concrete elevated water tanks

elevated tanks are important structures in storing vital products, such as petroleum products for cities and industrial facilities, as well as water storage. these structures have various types and are constructed in a way that a greater portion of their weight is concentrated at an elevation much about the base. damage to these structures during strong ground motions may lead to fire or other ...

متن کامل

Direct Displacement Based Design of Reinforced Concrete Elevated Water Tanks Frame Staging

Elevated water tanks supported by the reinforced concrete (RC) Staging are classified as inverted pendulum structures. These are considered as structures of high post-earthquake importance and should remain functional after the seismic events. National codes of various countries recommend Force-Based Design (FBD) procedure for water tank staging, which does not ensure nonlinear performance leve...

متن کامل

seismic behavior assessment of concrete elevated water tanks

elevated tanks are very important structures and consist of various types. water supply is vital to control fires during earthquakes. also they are utilized to store different products, like petroleum supplies in cities and industrial zones. damage to these structures during strong ground motions may lead to fire or other hazardous events. elevated tanks should stay functional after and before ...

متن کامل

Evaluation of Seismic Behaviour of Ferrocement Elevated Water Tanks by Using Ambient Vibrations Tests

In this study a series of ambient vibration tests on the triple ferrocement elevated water tanks with 150 cubic meters volume, is carried out. In order to verify the dynamic characteristics of full, half-full and one full tanks (mass eccentric system), the different arrangements of sensors are used. The effects of base rotation are also considered in the tests. Natural frequencies and mode shap...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of civil engineering

جلد ۸، شماره ۳، صفحات ۲۰۴-۲۲۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023