optimization study for bnct facility based on a dt neutron generator

نویسندگان

j.g. fantidis department of electrical engineering, technological education institute of eastern macedonia and thrace, saint loucas, kavala, greece

a. antoniadis cardiovascular division, brigham and women's hospital, harvard medical school, boston, usa

چکیده

background: a boron neutron capture therapy (bnct) facility, based on a dt neutron generator, with the final goal to find out a potential, alternative, solution to existing bnct treatment facilities which are based on nuclear reactors is examined. materials and methods: with the aim of the mcnp4b monte carlo code different beam-shaping assembly (bsa) configurations were considered. lead was selected as reflector material while cf2, d2o, fluental, pbf4, pbf2, bif3, bif5, mgf2, al2o3, alf3, tif3, bed2, caf2 and 7lif were examined as spectrum shifters. in order to improve the quality of the beam titanium, nickel-60, iron and titanium alloy (ti6al14v) were simulated as fast neutrons filters while lead and bismuth were considered as gamma filters. results: an extensive set of calculations performed with mcnp4b monte carlo code have shown that the combination of 7lif which accommodates a conic part made of d2o, then followed by a tif3 layer is the optimum moderator design. the use of three different materials for further reduction of fast neutrons, thermal neutrons and gamma rays is necessary. 60ni, cd and bi were chosen respectively for these purposes. the epithermal neutron flux obtained at the beam exit window turned out to be 3.94×109 n cm-2 s-1 while fulfilling all the recommended iaea in-air figure of merit (fom) criteria. the assessment of the dose profiles in head phantom and the in-phantom fom are also presented. conclusion: the proposed assembly configuration may provide an attractive option for centers wishing to install a bnct facility.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimization study for BNCT facility based on a DT neutron generator

Background: A Boron Neutron Capture Therapy (BNCT) facility, based on a DT neutron generator, with the final goal to find out a potential, alternative, solution to existing BNCT treatment facilities which are based on nuclear reactors is examined. Materials and Methods: With the aim of the MCNP4B Monte Carlo code different beam-shaping assembly (BSA) configurations were considered. Lead was sel...

متن کامل

Optimised BNCT facility based on a compact D-D neutron generator

Background: Boron Neutron Capture Therapy (BNCT) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. Thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. Materials and Me...

متن کامل

optimised bnct facility based on a compact d-d neutron generator

background: boron neutron capture therapy (bnct) is a very promising treatment for patients suffering gliobastoma multiforme, an aggressive type of brain cancer, where conventional radiation therapies fail. thermal neutrons are suitable for the direct treatment of cancers which are located at near-tissue-surface deep-seated tumors need harder, epithermal neutron energy spectra. materials and me...

متن کامل

Epithermal Neutron Beam Generator Design for Bnct

BNCT is a radiotherapy modality based on the neutron capture and fission reactions that occur when boron-10 is irradiated by thermal neutrons. This reaction generates alpha and lithium that produce high density of ionizations in close to the reaction site. The concept provides high absorbed doses into the cancerous cells preserving the adjacent healthy tissues. Nowadays, the available neutron s...

متن کامل

A D-D/D-T Fusion Reaction Based Neutron Generator System for Liver Tumor BNCT

Boron-neutron capture therapy (BNCT) is an experimental radiation treatment modality used for highly malignant tumor treatments. Prior to irradiation with low energetic neutrons, a B compound is located selectively in the tumor cells. The effect of the treatment is based on the high LET radiation released in the B(n,α)Li reaction with thermal neutrons. BNCT has been used experimentally for brai...

متن کامل

Evaluation of a Neutron Beam Generation Facility for the Accelerator-Based BNCT

The important things in designing facilities for BNCT are to obtain neutron beams with appropriate energy spectrum and intensity for efficient treatment. In recent years, at several universities, accelerator-based BNCT facilities were designed, which are composed of target and beam shaping assembly to generate epithermal neutron beams[1]. As a previous study, target system[2][3] and a beam shap...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۳، شماره ۱، صفحات ۱۳-۲۴