new approach for attenuation correction in spect images, using linear optimization

نویسندگان

a. vahidian kamyad department of mathematic, ferdowsi university, mashad, iran

m.h. noori eskandari department of mathematic, ferdowsi university, mashad, iran

m. naji midani department of medical physics, mashad university for medical sciences, mashad, iran

m. hajizadeh saffar department of medical physics, mashad university for medical sciences, mashad, iran

چکیده

background: photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of spect images and results to errors in accuracy of quantitative measurements. this can be corrected via different physical or mathematical approaches. as the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘piece wise linearization’ (pwl) is introduced and to substantiate its validity for spect image reconstructions, a phantom study is performed. material and methods: a spect scan of a homemade heart phantom filled with 2 mci 99mtc was acquired by dual head siemens e.cam gamma camera equipped with lehr collimator. row data of the scan were transferred in dicom format to a pc computer for reconstruction of the images using mlem iterative algorithm in matlab software. results: attenuation map of the phantom µ(x) were derived using pwl with linear optimization approach. based on that, the attenuation corrected spect image of the phantom were reconstructed and compared with non-corrected image, using mlem iterative algorithm. comparison of the corrected and non-corrected images confirmed with ct attenuation correction method. conclusion: attenuation correction in spect image can be achieved successfully, using emission data and piecewise linearization with linear optimization approach. the corrected image of f(x) and attenuation map µ(x)  of the heart phantom using this approach promise acceptable image quality for diagnostic clinical use. iran. j. radiat. res., 2010 8 (2): 111-116

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece Wise Line...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images

  Objective(s): In SPECT, the sinogram contains scatter and lack of attenuated counts that degrade the reconstructed image quality and quantity. Many techniques for attenuation and scatter correction have been proposed. An acceptable method of correction is to incorporate effects into an iterative statistical reconstruction. Here, we propose new Maximum Likelihood Expectation Maximiz...

متن کامل

A new approach to scatter correction in SPECT images based on Klein_Nishina equation

Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...

متن کامل

evaluation of attenuation correction process in cardiac spect images

introduction: attenuation correction is a useful process for improving myocardial perfusion spect and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). attenuation artifacts are a common problem in myocardial perfusion spect. the aim of this study was to compare the effect of attenuation correction using different attenuation maps and different...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۸، شماره ۲، صفحات ۱۱۱-۱۱۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023