simultaneous application of fenton – electrochemical reactor for removal of organic loading in biological waste sludge

نویسندگان

گاگیک بدلیانس قلی کندی

دانشیار مهندسی محیط زیست ،آب و فاضلاب، دانشگاه شهید بهشتی، پردیس فنی مهندسی شهید عباسپور حمیدرضا مسیحی

کارشناس ارشد مهندسی عمران، آب و فاضلاب، دانشگاه شهید بهشتی، پردیس فنی مهندسی شهید عباسپور مریم میرابی

استادیار مهندسی محیط زیست ، آب و فاضلاب، دانشگاه شهید بهشتی، پردیس فنی مهندسی شهیدعباسپور

چکیده

introduction             wastewater treatment using activated sludge process (asp) produces huge amounts of sludge that must be treated by efficient methods. wastewater sludge handling is one of the most important economic-technical challenges of wastewater treatment projects. conventional methods for this purpose are very time consuming, expensive and in lots of cases have limited success. in recent years the electrochemical oxidation techniques have been progressively used for water and wastewater treatment process. many reports showed that these methods are very effective to eliminate or decrease the organic loading content of wastewater and sludge. combination of electrochemical reactions and fenton process has widely been studied for the destruction of organics and bio-refractory pollutants contained in industrial wastewater by highly oxidative hydroxyl radicals formed from reaction of h2o2 with fe2+. this method offers more advantages than the chemical fenton process due to the high efficiency of fenton reagents (e.g., h2o2) utilization and lower retention time. the integrated fenton and electrochemical reactor were used to reduce concentration of volatile suspended solids in sludge. high consumption rate of divalent iron ions is one of the disadvantages of fenton method compared with its reduction. in this research, the electrochemical method has been used to solve this problem. the electrochemical method increases the reduction rate of divalent iron by converting the trivalent iron ions into the bivalent ones and it reduces the production of iron sludge. in this research, the effective parameters including ratio of iron to hydrogen peroxide, ph, retention time, concentration of hydrogen peroxide and the amount of electric current were investigated.   materials and methods in the present study we have evaluated the efficiency of fenton-electrochemical process in reduction of organic contents of secondary sludge of mahallati asp wastewater treatment plant. this plant is located in tehran, with treatment capacity of 4800m3 per day and operates in extended aeration process. table 1 shows the specifications of the investigated sludge. our reagents were h2o2 and fe2+.  the evaluated fenton-electrochemical reactor has been shown in figure1. the reactor contains two grafit anodes and two grafit cathods. the electrodes dimentions were 1mm*140mm*60mm, and the distance between them is 1.5 cm. the volume of reactor has been selected 0.9 l. we used the mechanical mixer  instead of electromagnetic stirer because of the sensitivity of fe2+ ions to electromagnetic materials. the temperature during the test was between 13.8 and 15.6 ˚c. all tests were conducted according to standard methods (apha, 1999) and each part of experiments was repeated three times.   property value ph 6.53-7.33 temperature(˚c) 13.8-15.6 cod (mg/lit) 6051-11164 vss ( mg/lit) 3536-7782 vs ( mg/lit) 4086-8382 tss (mg/lit) 4088-8432 vss/tss 0.86-0.92      figure 1. the evaluated ef reactor                                            table 1. investigated sludge specifications   result and discution             the removal of volatile suspended solids (vss) as the efficiency factor haveevaluted the effects of the ration of fe2+ concentration on h2o2 concentration ( [fe2+]/[ h2o2]), time,  ph, h2o2 concentration and current density as the effective process operation parameters. to obtain the most efficient we have investigated the operational parameter serily. the firest parameter that is studied is [fe2+]/[ h2o2] . figure 2 showes the effect of [fe2+]/[ h2o2] to removal of vss. regarding to the diagram, the removal of vss increases sharply as [fe2+]/[ h2o2] increases to 0.58 (optimum point) and reach its maximum in this point and is constant to about 1.015 and then decreases slightly. the second parameter is ph. it has been studied in the optimum point of [fe2+]/[ h2o2]. adjustment of ph has been done by 98% sulfuric acid. figure 3 shows that the removal of vss is constant by increasing the ph up to 3, and then starts to decrease. the maximum vss removal (approximately 72%) was attained in ph=3.1. oxidation efficiency essentially decreases at ph values lower than 3. figure 4 shows the relation of vss removal and time. the time was assessed in the maximum point of the last two parameters. according to the diagram, the vss removal increases by time and reaches its maximum in approximately 6 hours and then is constant.                        figure 2. vss removal and [fe2+]/[ h2o2] relationship   fig.3: vss removal and ph relationship    fig.4: vss removal and time relationship     in order to attain the best concentration of fe2+ and h2o2, we studied the effect of h2o2 concentration on vss removal. the optimum ratio of [fe2+]/[ h2o2] can be attained from figure2. fe2+concentration are also resulted by determining the optimum h2o2 concentration. the tests carried out in the most effective point of prior parameters and the results has been shown in figure 5. according to the diagram, the highest vss  removal was obtained when the h2o2 concentration is approximately 1568mg/l. finally, after determining the optimum point for ( [fe2+]/[ h2o2]), detention time,  ph, h2o2 concentration, and the effect of current density was evaluated. current density improves the reduction of trivalent iron to divalent iron, i.e., it enhances the efficiency of fenton process. according to figure 6, the maximum vss removal  has been reached in (650-750) ma current density. the remained fe2+ concentration has also been investigated. as shawn in the figure 7, approximately (40-70)% of inserted [fe2+] adsorbed on the electrodes, (7-15)% was remained in the sludge layer and (23-45)% in the sludge liquor.                                    figure 5. vss removal and [ h2o2] relationship              figure 6. vss removal and current density relationship               figure 7. remained and consumed [ fe2+]relationship   fenton and electrochemical-fenton were compared on an equal basis. according to the figure 8, the efficiency of electrochemical-fenton is 76%, while the efficiency of fenton is 22%. figure 9 shows the current density of energy consumption. by increasing the current density rate, energy consumption increases exponentially.                                                                       figure 8. vss removal efficiency of fenton and fenton-electrochemical regarding detention time              figure 9. current density of energy consumption in fenton-                                                                                                                                                                        electrochemical   conclusions even if in the recent decades many efforts have been done in order to enhance usual sludge treatment or commence novel more efficient methods, lots of researches have focused on techno-economical issues carefully. the key purpose of the researches is to eliminate the organic load of sludge and improve its quality in order to be reused in various applications like fertilizer in agriculture. in this study we have evaluated a combined fenton-electrochemical process with the aim of stabilizing excessive biological sludge of municipal wastewater treatment plant. for this purpose, several determining parameters have been selected and investigated in a lab-scale pilot. the results showed that the system has preserved its stability in a wide range of ph (3-7), also the organic load of the sludge decreased noticeably (maximum decreasing efficiency of the sludge was approximately 81%). comparison of the results of fenton or other usual systems and combined fenton-electrochemical process showed that the later system is appropriate and efficient method to get better quality of stabilized sludge and operational conditions.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effect of Organic Loading on Propylene Glycol Removal Using Fixed Bed Activated Sludge Hybrid Reactor

Propylene glycol is discharged to the surface and underground waters and vicinity soils via industrial wastewater effluents, posing many health and environmental risks. The main goal of this study was to remove propylene glycol from synthetic wastewater in a fixed bed activated sludge reactor. To observe the effects of organic loading on bioreactor performance, the organic loading was increased...

متن کامل

part a: application of n-(p-toluenesulfonyl) imidazole (tsim) and triphenylphosphine/carbon tetrachloride in several organic transformations part b: application of 8-bromocaffeine for synthesis of some novel 8-caffeinyl derivatives

بخش اول این پایان نامه به طور عمده بر توسعه کاربردهای جدید n-(پارا-تولوئن سولفونیل) ایمیدازول (tsim) و تری فنیل فسفین/ تتراکلرید کربن در تبدیل گروههای عاملی به یکدیگر استوار است. نظر به تنوع زیاد، دردسترس بودن، سمیت کمتر و نقل و انتقال آسان تر الکل ها نسبت به آلکیل هالیدها، تبدیل مستقیم گروه هیدروکسیل به گروه های عاملی دیگر مثل آزید، نیتریل و استر یکی از مهم ترین تبدیلات در سنتزهای آلی است. با ...

15 صفحه اول

Photo-biological Reactor for Organic Waste Consumption and Hydrogen Production

The current global economy relies on fossil fuels, therefore air pollution concentration rises every day. With a growing population and industrial development, comes an increase in energy demand, need for greater sanitary infrastructure, and an urge for minimal ecosystem damage. Many successful articles about biological hydrogen production were recently approved by major international journals,...

متن کامل

Application of mine waste for wastewater treatment: Efficient organic pollutant removal

In this research, a high porous silicate mining waste that was prepared from Syah Kamar Polymetal Porphyry mine in order to malachite green dye (MG) removal has been applied. The characterization of this natural mineral was determined using the XRD, XRF, SEM and FT-IR analysis. The MG adsorption onto high porous activated waste was studied based on the parameters of pH, temperature, adsorbent d...

متن کامل

application and construction of carbon paste modified electrodes developed for determination of metal ions in some real samples

ساخت الکترودهاِی اصلاح شده ِیکِی از چالشهاِی همِیشگِی در دانش شیمِی بوِیژه شیمِی تجزیه مِی باشد ،که با در نظر گرفتن سادگِی ساخت، کاربردی بودن و ارزان بودن روش مِی توان به باارزش بودن چنِین سنسورهاِی پِی برد.آنچه که در ادامه آورده شده به ساخت و کاربرد الکترودهاِی اصلاح شده با استفاده از نانو ذرات در اندازه گِیرِی ولتامترِی آهن وکادمِیم اشاره دارد. کار اول اختصاص دارد به ساخت الکترود خمِیر کربن اصلاح شده با لِیگاند داِ...

15 صفحه اول

an application of equilibrium model for crude oil tanker ships insurance futures in iran

با توجه به تحریم های بین المملی علیه صنعت بیمه ایران امکان استفاده از بازارهای بین المملی بیمه ای برای نفتکش های ایرانی وجود ندارد. از طرفی از آنجایی که یکی از نوآوری های اخیر استفاده از بازارهای مالی به منظور ریسک های فاجعه آمیز می باشد. از اینرو در این پایان نامه سعی شده است با استفاده از این نوآوری ها با طراحی اوراق اختیارات راهی نو جهت بیمه گردن نفت کش های ایرانی ارائه نمود. از آنجایی که بر...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
محیط شناسی

جلد ۴۰، شماره ۱، صفحات ۱۷۷-۱۸۸

کلمات کلیدی
introduction             wastewater treatment using activated sludge process (asp) produces huge amounts of sludge that must be treated by efficient methods. wastewater sludge handling is one of the most important economic technical challenges of wastewater treatment projects. conventional methods for this purpose are very time consuming expensive and in lots of cases have limited success. in recent years the electrochemical oxidation techniques have been progressively used for water and wastewater treatment process. many reports showed that these methods are very effective to eliminate or decrease the organic loading content of wastewater and sludge. combination of electrochemical reactions and fenton process has widely been studied for the destruction of organics and bio refractory pollutants contained in industrial wastewater by highly oxidative hydroxyl radicals formed from reaction of h2o2 with fe2+. this method offers more advantages than the chemical fenton process due to the high efficiency of fenton reagents (e.g. h2o2) utilization and lower retention time. the integrated fenton and electrochemical reactor were used to reduce concentration of volatile suspended solids in sludge. high consumption rate of divalent iron ions is one of the disadvantages of fenton method compared with its reduction. in this research the electrochemical method has been used to solve this problem. the electrochemical method increases the reduction rate of divalent iron by converting the trivalent iron ions into the bivalent ones and it reduces the production of iron sludge. in this research the effective parameters including ratio of iron to hydrogen peroxide ph retention time concentration of hydrogen peroxide and the amount of electric current were investigated.   materials and methods in the present study we have evaluated the efficiency of fenton electrochemical process in reduction of organic contents of secondary sludge of mahallati asp wastewater treatment plant. this plant is located in tehran with treatment capacity of 4800m3 per day and operates in extended aeration process. table 1 shows the specifications of the investigated sludge. our reagents were h2o2 and fe2+.  the evaluated fenton electrochemical reactor has been shown in figure1. the reactor contains two grafit anodes and two grafit cathods. the electrodes dimentions were 1mm*140mm*60mm and the distance between them is 1.5 cm. the volume of reactor has been selected 0.9 l. we used the mechanical mixer  instead of electromagnetic stirer because of the sensitivity of fe2+ ions to electromagnetic materials. the temperature during the test was between 13.8 and 15.6 ˚c. all tests were conducted according to standard methods (apha 1999) and each part of experiments was repeated three times.   property value ph 6.53 7.33 temperature(˚c) 13.8 15.6 cod (mg/lit) 6051 11164 vss ( mg/lit) 3536 7782 vs ( mg/lit) 4086 8382 tss (mg/lit) 4088 8432 vss/tss 0.86 0.92      figure 1. the evaluated ef reactor                                            table 1. investigated sludge specifications   result and discution             the removal of volatile suspended solids (vss) as the efficiency factor haveevaluted the effects of the ration of fe2+ concentration on h2o2 concentration ( [fe2+]/[ h2o2]) time ph h2o2 concentration and current density as the effective process operation parameters. to obtain the most efficient we have investigated the operational parameter serily. the firest parameter that is studied is [fe2+]/[ h2o2] . figure 2 showes the effect of [fe2+]/[ h2o2] to removal of vss. regarding to the diagram the removal of vss increases sharply as [fe2+]/[ h2o2] increases to 0.58 (optimum point) and reach its maximum in this point and is constant to about 1.015 and then decreases slightly. the second parameter is ph. it has been studied in the optimum point of [fe2+]/[ h2o2]. adjustment of ph has been done by 98% sulfuric acid. figure 3 shows that the removal of vss is constant by increasing the ph up to 3 and then starts to decrease. the maximum vss removal (approximately 72%) was attained in ph=3.1. oxidation efficiency essentially decreases at ph values lower than 3. figure 4 shows the relation of vss removal and time. the time was assessed in the maximum point of the last two parameters. according to the diagram the vss removal increases by time and reaches its maximum in approximately 6 hours and then is constant.                        figure 2. vss removal and [fe2+]/[ h2o2] relationship   fig.3: vss removal and ph relationship    fig.4: vss removal and time relationship     in order to attain the best concentration of fe2+ and h2o2 we studied the effect of h2o2 concentration on vss removal. the optimum ratio of [fe2+]/[ h2o2] can be attained from figure2. fe2+concentration are also resulted by determining the optimum h2o2 concentration. the tests carried out in the most effective point of prior parameters and the results has been shown in figure 5. according to the diagram the highest vss  removal was obtained when the h2o2 concentration is approximately 1568mg/l. finally after determining the optimum point for ( [fe2+]/[ h2o2]) detention time ph h2o2 concentration and the effect of current density was evaluated. current density improves the reduction of trivalent iron to divalent iron i.e. it enhances the efficiency of fenton process. according to figure 6 the maximum vss removal  has been reached in (650 750) ma current density. the remained fe2+ concentration has also been investigated. as shawn in the figure 7 approximately (40 70)% of inserted [fe2+] adsorbed on the electrodes (7 15)% was remained in the sludge layer and (23 45)% in the sludge liquor.                                    figure 5. vss removal and [ h2o2] relationship              figure 6. vss removal and current density relationship               figure 7. remained and consumed [ fe2+]relationship   fenton and electrochemical fenton were compared on an equal basis. according to the figure 8 the efficiency of electrochemical fenton is 76% while the efficiency of fenton is 22%. figure 9 shows the current density of energy consumption. by increasing the current density rate energy consumption increases exponentially.                                                                       figure 8. vss removal efficiency of fenton and fenton electrochemical regarding detention time              figure 9. current density of energy consumption in fenton electrochemical   conclusions even if in the recent decades many efforts have been done in order to enhance usual sludge treatment or commence novel more efficient methods lots of researches have focused on techno economical issues carefully. the key purpose of the researches is to eliminate the organic load of sludge and improve its quality in order to be reused in various applications like fertilizer in agriculture. in this study we have evaluated a combined fenton electrochemical process with the aim of stabilizing excessive biological sludge of municipal wastewater treatment plant. for this purpose several determining parameters have been selected and investigated in a lab scale pilot. the results showed that the system has preserved its stability in a wide range of ph (3 7) also the organic load of the sludge decreased noticeably (maximum decreasing efficiency of the sludge was approximately 81%). comparison of the results of fenton or other usual systems and combined fenton electrochemical process showed that the later system is appropriate and efficient method to get better quality of stabilized sludge and operational conditions.

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023