optimization conditions for determination of cosmetic preservatives using ion-exclusion chromatography

نویسندگان

h. sid kalal

j. rafiei

f. bani

a.r. khanchi

h. hoveidi

چکیده

an ion chromatography (ic) method for simultaneous determination of benzoic, salicylic and sorbic acids was developed. in this method the samples were purified by solid-phase extraction. the analytes were then eluted with methanol from c18 cartridge. the separation was performed on ion-exclusion column by an isocratic elution with 0.25 mmol /l sulfuric acid solution containing 20% (v/v) acetone as elute. the calibration curves showed good linearity with suppressed conductivity detection.under this condition, separation of the three components was achieved in less than 23 min. the detection limit calculated as the concentration corresponding to three times the background noise, was 0.1, 0.15 and 0.2 mg/ l for benzoic acid, salicylic acid and sorbic acid respectively. the method was successfully applied to analysis of various cosmetic products.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

optimization conditions for determination of cosmetic preservatives using ion-exclusion chromatography

an ion chromatography (ic) method for simultaneous determination of benzoic, salicylic and sorbic acids was developed. in this method the samples were purified by solid-phase extraction. the analytes were then eluted with methanol from c18 cartridge. the separation was performed on ion-exclusion column by an isocratic elution with 0.25 mmol /l sulfuric acid solution containing 20% (v/v) acetone...

متن کامل

Ion Exclusion Chromatography: Liquid Chromatography

terials, operated in a pressure-driven mode, plotted as a function of inverse temperature. This Rgure is intended to give some appreciation of the Suxes that are attainable; however, they are not normalized to a given partial pressure gradient or thickness of membrane, and thus the Suxes are not directly comparable. Taking a value of between 10 and 100 L m 2 min 1 as the level of oxygen Sux nee...

متن کامل

Modeling of ion-exclusion and vacancy ion-exclusion chromatography in analytical and concentration overload conditions.

Ion-exclusion chromatography (IEC) finds applications in various different analytical separations of weak acids. Pure, deionized water or a diluted, aqueous solution of a strong mineral acid (such as, e.g., sulphuric acid) is used as the mobile phase, whereas a typical stationary phase is a strongly acidic resin in the H(+) form (e.g., the sulfonated polystyrene-divinylbenzene resin with a high...

متن کامل

Separation of preservatives in cosmetic products by micellar electrokinetic chromatography.

This paper describes the methodological optimization and validation of a simple micellar electrokinetic chromatography for the rapid simultaneous separation of 2-methyl-4-isothiazolin-3-one, methylparaben, ethylparaben, propylparaben, and butylparaben. By using a 30 mM phosphate buffer (pH 7.2) containing 30 mM sodium dodecyl sulfate (SDS), an applied voltage of 10 kV and a separation temperatu...

متن کامل

Ion exclusion chromatography of aromatic acids.

The determination of aromatic acids by ion exclusion chromatography is challenging due to peak tailing and the long retention time of hydrophobic solutes. This review discusses the retention mechanisms and the factors affecting retention, eluents and detection methods used in ion exclusion chromatography of aromatic acids such as mono-, di-, tri- and tetra-carboxylic acids, amino acids, sulfona...

متن کامل

development of different optical methods for determination of glucose using cadmium telluride quantum dots and silver nanoparticles

a simple, rapid and low-cost scanner spectroscopy method for the glucose determination by utilizing glucose oxidase and cdte/tga quantum dots as chromoionophore has been described. the detection was based on the combination of the glucose enzymatic reaction and the quenching effect of h2o2 on the cdte quantum dots (qds) photoluminescence.in this study glucose was determined by utilizing glucose...

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
international journal of environmental research

ناشر: university of tehran

ISSN 1735-6865

دوره 4

شماره 2 2010

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023