electrochemical determination of calcium dobesilate on graphene glassy carbon modified electrode

نویسندگان

maryam iman

fariba dashtestani

zahra zafari

mehdi kamali

چکیده

graphene modified glassy carbon electrodes have been developed for the determination of calcium dobesilate in pharmaceutical formulations. the prepared graphene and cnts were used as a conductive substrate for electrochemical study of calcium dobesilate. the direct electrochemistry of calcium dobesilate showed a reversible cyclic voltammogram with a formal potential of 133 mv (vs. ag/agcl) for graphene modified electrodes in 0.1 m phosphate buffer. the linear concentration range of the sensor is 30-120 ngr for graphene modified electrode, respectively. the lifetime of biosensor is more than 2 weeks. the proposed modified electrode provides a new promising and alternative way to detect calcium dobesilate.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Study and Electrochemical Determination of Tyrosine at Graphene Nanosheets Composite Film Modified Glassy Carbon Electrode

A graphene nanosheets (GNS) film coated glassy carbon electrode (GCE) was fabricated for sensitive determination of tyrosine (Tyr). The GNS-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. The voltammetric techniques were employed to study electro-oxidation of Tyr. The results revealed that the modified electrode showed an electrocatalyt...

متن کامل

Electrochemical Chiral Recognition of Naproxen Using L-Cysteine/Reduced Graphene Oxide Modified Glassy Carbon Electrode

The electrochemical response of S- and R-naproxen enantiomers was investigated on L-cysteine/reduced graphene oxide modified glassy carbon electrode (L-Cys/RGO/GCE). The production of the reduced graphene oxide and L-cysteine on the surface of the glassy carbon electrode was done by using electrochemical processes. Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were us...

متن کامل

study and electrochemical determination of tyrosine at graphene nanosheets composite film modified glassy carbon electrode

a graphene nanosheets (gns) film coated glassy carbon electrode (gce) was fabricated for sensitive determination of tyrosine (tyr). the gns-based sensor was characterized by scanning electron microscope and electrochemical impedance spectroscopy. the voltammetric techniques were employed to study electro-oxidation of tyr. the results revealed that the modified electrode showed an electrocatalyt...

متن کامل

Electrochemical Sensor for Determination of Fenitrothion at Multi-wall Carbon Nanotubes Modified Glassy Carbon Electrode

A sensor, based on multi-wall carbon nanotubes modified glassy carbon electrode (MWCNT/GCE), was developed for determination of fenitrothion. Determining the surface area of MWCNT/GCE showed that this surface is three times more active than that of a glassy carbon electrode. The experimental parameters, such as the amount of MWCNTs, pH of the fenitrothion solution, preconcentration potential an...

متن کامل

Electrochemical behavior and voltammetric determination of theophylline at a glassy carbon electrode modified with graphene/nafion.

An ultrasensitive voltammetric sensor, a simply coated graphene-Na?on suspension on a glass carbon electrode surface, was fabricated and used to investigate the electrochemical behavior of theophylline as described in the present paper. The results indicated that this voltammetric sensor exhibited a special recognition capacity to determine theophylline as well as having high sensitivity due to...

متن کامل

Electrochemical behavior and determination of clozapine on a glassy carbon electrode modified by electrochemical oxidation.

The adsorptive and electrochemical behaviors of clozapine (CLZ) were investigated on a glassy carbon electrode that was electrochemically treated by anodic oxidation at +1.8 V, following potential cycling in the potential range from -0.8 to 1.0 V vs. Ag/AgCl reference electrode. Based on the obtained electrochemical results, an electrochemical-chemical (EC) mechanism was proposed to explain the...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
applied biotechnology reports

جلد ۳، شماره ۱، صفحات ۳۷۳-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023