comparison of dentinal crack formation with reciproc, mtwo and protaper root canal preparation systems

نویسندگان

kiumars nazari moghaddam department of endodontics, dental school, shahed university, tehran, ir iran

seyed lotfoallah derakhshan endodontics private practice, tehran, ir iran

mohammad adeli department of endodontics, dental school, shahed university, tehran, ir iran; department of endodontics, dental school, shahed university, tehran, ir iran

ehsan hamzelouei moghadam department of endodontics, dental school, shahed university, tehran, ir iran

چکیده

conclusions regarding the study limitations, dentinal cracks were observed in all files and distances from the apex. although there was more crack incidence in protaper files, no significant differences were noted regarding the studied systems and sections from the apex. materials and methods in an experimental in vitro trial, 80 maxillary and mandibular first molars were selected and their crowns and distal roots were cut. the roots were then examined to remove any previous cracks and defects. an impression polyether material was used to simulate teeth periodontal ligament (pdl). the teeth were divided to four experimental groups (n = 20) and prepared using reciproc, mtwo and protaper or remained unprepared as a control group. the specimens were then sectioned horizontally on 3, 5 and 9 mm from the apex and number of micro-cracks was determined by stereomicroscope. the incidence of dentinal cracks on different systems or sections were statistically analyzed by means of the chi-square test. background instrumentation with rotary instruments could potentially cause dentinal cracks possibly leading to tooth fracture. reciproc files require a single file to finalize the root canal preparation and the effect of this procedure has not been compared with other systems. results dentinal defects on 3-mm, 5-mm and 9-mm sections from the apex were noted in 10 (5.6%); 7 (3.9%) and 9 (5.0%) samples of all, respectively. following canal preparation using reciproc, protaper and mtwo systems, the defects were observed in 7 (3.9%), 12 (6.7%) and 7 (3.9%) the sections, respectively. no significant differences were observed regarding the defect incidence on the studied instrumentation files or sections. objectives the aim of this study was to compare the incidence of dentinal micro-cracks following root canal preparations with protaper, mtwo and reciproc files.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of Dentinal Crack after Root Canal Preparation by ProTaper Universal, Neolix and SafeSider Systems

Introduction This study aimed to compare the incidence of dentinal crack formation by instrumentation with ProTaper Universal system (rotary, multi-file system), SafeSider (reciprocation movement, multi-file system) and Neolix (rotary, single-file system). Methods and Materials In this in vitro study, 60 freshly extracted mandibular first molars were randomly divided into three experimental g...

متن کامل

Dentinal crack formation during root canal preparations by the twisted file adaptive, Reciproc and WaveOne instruments

OBJECTIVE This study aimed to compare the frequency of dentinal microcracks after root canal shaping with 2 reciprocating (Reciproc and WaveOne) and 1 combined continuous reciprocating motion twisted files adaptive (TFA) rotary system. MATERIALS AND METHODS Ninety molars were chosen and divided into three groups of 30 each. Root canal preparation was achieved by using Reciproc R25, Primary Wa...

متن کامل

Effects of Reciproc, Mtwo and ProTaper Instruments on Formation of Root Fracture

INTRODUCTION The aim of this study was to compare the formation of dentinal crack and craze lines in the root dentin during root canal preparation with three different NiTi endodontic systems, naming Reciproc (RCP), ProTaper Universal (PTU) and Mtwo. METHODS AND MATERIALS One hundred extracted mandibular premolars with single canals were selected and decoronated. The teeth were randomly divid...

متن کامل

In-vitro Comparison of NiTi Tee, RaCe and Protaper Instruments in Dentinal Crack Formation

Background and Aim:Root canal preparation with rotary instruments may cause dentinal cracks leading to tooth fracture. The aim of this study was to compare three different rotary systems ProTaper, RaCe and Niti Tee on formation of dentinal cracks following root canal preparation. Materials and Methods: In this experimental study, 50 extracted mandibular first molars were selected. Teeth having ...

متن کامل

Effect of different torques on dentinal crack formation following canal preparation using neoniti rotary system

Introduction: The aim of this study was to determine the incidence of dentinal cracks in the  mesial root of maxillary molar during canal preparation using Neoniti system in different torque settings. Materials &Methods: In this in-vitro study, 60 maxillary molars extracted for various reasons were selected. The teeth were divided into 4 groups: one group(n=15) without preparation was con...

متن کامل

effects of reciproc, mtwo and protaper instruments on formation of root fracture

introduction: the aim of this study was to compare the formation of dentinal crack and craze lines in the root dentin during root canal preparation with three different niti endodontic systems, naming reciproc (rcp), protaper universal (ptu) and mtwo. methods and materials: one hundred extracted mandibular premolars with single canals were selected and decoronated. the teeth were randomly divid...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
middle east journal of rehabilitation and health studies

جلد ۳، شماره ۳، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023