overnight dexamethasone suppression test in the diagnosis of cushing's disease

نویسندگان

fatemeh esfahanian department of endocrinology, imam khomeini hospital, school of medicine, tehran university of medical sciences, tehran, iran.

rozana kazemi department of endocrinology, imam khomeini hospital, school of medicine, tehran university of medical sciences, tehran, iran.

چکیده

realizing the cause of cushing's syndrome (cs) is one of the most challenging processes in clinical endocrinology. the long high dose dexamethasone suppression test (standard test) is costly and need an extended inpatient stay. in this study we want to show the clinical utility of the overnight 8 mg dexamethasone suppression test (dst) for differential diagnosis of cs in a referral center. retrospectively from 2002-2005 we selected the patients of endocrinology ward in imam hospital who were admitted with the diagnosis of cushing syndrome and had 8 mg dst (modified test) along with classic dst. in modified test a decrease in an 8 am serum cortisol level of 50% or more is thought to indicate suppression and we compared the results of modified test with standard test. this test had been done on 42 patients: 10 male (23%) and 32 female (76%). the mean age of patients was 31.39 (15-63), 32 with proven pituitary cushing's disease, 7 with primary adrnal tumors and 3 with ectopic acth syndrome. the standard test according to 50% suppression of ufc had 90.62% sensitivity, and according to 90% suppression had 43.75% sensitivity. the sensitivity of this test was 71.85% for serum cortisol suppression. the modified test (8 mg overnight dst) had 78% sensitivity. all of these tests had 100% specificity for the diagnosis of cushing's disease. the positive predictive vale (ppv) of all of these tests was 100%. the negative predictive value (npv) of modified test for the diagnosis of cushing's disease was 58.82%. in standard test the npv of serum cortisol was 52.6%, ufc 50% had 76.9% npv and ufc 90% had 35.7% npv. the results of serum cortisol suppression in modified test is better than standard test. although 50% suppression of ufc in standard test had greater sensitivity than modified test, collecting of urine is difficult, time consuming and needing hospitalization, so we advice modified test that is much simpler and more convenient instead of standard test in the first step of evaluating the cause of cushing's syndrome in referral centers.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Overnight dexamethasone suppression test in the diagnosis of Cushing's disease.

Realizing the cause of Cushing's syndrome (CS) is one of the most challenging processes in clinical endocrinology. The long high dose dexamethasone suppression test (standard test) is costly and need an extended inpatient stay. In this study we want to show the clinical utility of the overnight 8 mg dexamethasone suppression test (DST) for differential diagnosis of CS in a referral center. Retr...

متن کامل

Association between posttest dexamethasone and cortisol concentrations in the 1 mg overnight dexamethasone suppression test

It has been suggested that comparison of posttest dexamethasone and cortisol concentrations may improve the evaluation of the dexamethasone suppression test (DST) for Cushing's syndrome. In particular, this would be reasonable if posttest cortisol differs by dexamethasone levels within the range that is usually attained in the DST. Using fractional polynomial regression, we therefore studied th...

متن کامل

Comparison of efficacy between 1 mg overnight dexamethasone suppression test and 2-day low dose dexamethasone suppression test for diagnosis of Cushing's syndrome.

OBJECTIVE To assess the sensitivity and specificity of 1 mg overnight dexamethasone suppression test (ODST) and the 2-day low dose dexamethasone suppression test (LDST) for diagnosis of Cushing's syndrome, and to compare the accuracy of both tests using cutoff value at below 5 microg/dl and at below 1.8 microg/dl. MATERIAL AND METHOD The present study is a retrospective study, from 1971-2007,...

متن کامل

Dexamethasone Suppression Test in Depression

Baseline plasma Cortisol levels and response to dexamethasone in a group of twenty five patients with ma) or depressive disorder (MDD) and a control group of twenty five patients with psychiatric diagnoses other than MDD were estimated. The results of our study show that dexamethasone suppression test (DST) is a useful diagnostic aid in MDD with melancholia with a sensitivity of 46% and specifi...

متن کامل

Plasma dexamethasone levels in children given the dexamethasone suppression test.

To determine whether children who demonstrate dexamethasone suppression test (DST) nonsuppression have lower plasma dexamethasone levels than DST suppressors, we administered the DST to 73 patients ranging in age from 5-14 years. Plasma dexamethasone levels and postdexamethasone cortisol levels were measured at 4:00 PM on day 2. We found: (1) DST nonsuppressors had significantly lower plasma de...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
acta medica iranica

جلد ۲۰۱۰، شماره ۰۸، صفحات ۲۲۲-۲۲۵

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023