establishment of ct diagnostic reference levels in select procedures in south india

نویسندگان

a. saravanakumar department of applied science, psg college of technology, coimbatore 641 004, india

k. vaideki 1department of applied science, psg college of technology, coimbatore 641 004, india

k.n. govindarajan department of radiology, psg institute of medical science and research & hospitals, coimbatore 641004, india

b. devanand department of radiology, psg institute of medical science and research & hospitals, coimbatore 641004, india

چکیده

background: to suggest south india ct diagnostic reference levels (drls) by collecting radiation doses for the most commonly performed ct examinations. materials and methods: a pilot study investigated the most frequent ct examinations. 110 ct sites were asked to complete a survey booklet to allow the recording of ct parameters for each of 3 ct examinations during a 1 year time period. dose data such volumetric computed tomography dose index (ctdiv) and dose length product (dlp) on a minimum of 50 average-sized patients in each category were recorded to calculate a mean site ctdivol and dlp value. the rounded 75th percentile was used to calculate a drl for each site and the region by compiling all results. results are compared with international drl data. results: data were collected for 16,500 patients. all equipment had multislice capability (2-256 slices). drls are proposed using ctdivol (mgy) and dlp (mgy.cm) for ct head (47 and 1041 respectively), ct chest (10 and 445 respectively), and ct abdomen (12 and 550 respectively). these values are lower than current drls and comparable to other international studies. wide variations in mean doses are noted across the region. conclusion: baseline figures for south india ct drls are provided on the most frequently performed ct examinations. it was noted that there was a wide variation in mean doses among the ct scanners used during diagnosis. the differences in ct doses between ct scanner departments as well as identical scanners suggest a large potential for optimization of examinations.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Establishment of CT diagnostic reference levels in select procedures in South India

Background: To suggest South India CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. Materials and Methods: A pilot study investigated the most frequent CT examinations. 110 CT sites were asked to complete a survey booklet to allow the recording of CT parameters for each of 3 CT examinations during a 1 year time period. Dose...

متن کامل

Local Diagnostic Reference Levels for Common Computed Tomography Procedures at a Tertiary Hospital in South Africa

Introduction: An operational computed tomography (CT) scanner is a major source of human exposure to ionizing radiation. Exposure increases the risk of cancer and aplastic anaemia. All radiation exposures should be justified and optimized to meet the clinical objective. In order to avoid the administration of excessive radiation dose to patients, diagnostic reference l...

متن کامل

Establishment of CT diagnostic reference levels in Ireland.

OBJECTIVE To propose Irish CT diagnostic reference levels (DRLs) by collecting radiation doses for the most commonly performed CT examinations. METHODS A pilot study investigated the most frequent CT examinations. 40 CT sites were then asked to complete a survey booklet to allow the recording of CT parameters for each of 9 CT examinations during a 12-week period. Dose data [CT volume index (C...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Paediatric Dose AssessmentToward Establishment of National Diagnostic Reference Levels for Digital Radiography Examinations in Iran

Introduction: Paediatric patients deserve special attention because of the higher radiation risks compared with adults. The main purpose of this study is to determine patient dose and diagnostic reference level for Paediatric through Entrance Surface Dose (ESD) calculations in common X-ray examination and to establish Paediatric national DRLs in digital radiography in Iran. <...

متن کامل

Establishment of diagnostic reference levels for CT trunk examinations in the western region of Saudi Arabia.

Diagnostic reference levels (DRLs) are an important optimisation tool, which aid in identifying abnormally high dose levels. These are currently not available in Saudi Arabia, and this research aims to remedy this. CT dose data (DLP and CTDIvol) were collected for a minimum number of 10 adult patients of average size (60-80 kg) presenting for a range of CT examinations from public hospitals in ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiation research

جلد ۱۴، شماره ۴، صفحات ۳۴۱-۳۴۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023