wavelength region selection and spectrophotometric simultaneous determination of naphthol isomers based on net analyte signal

نویسندگان

ahmadreza amraei

department of chemistry, faculty of science islamic azad university, arak branch, arak, iran ali niazi

department of chemistry, faculty of science islamic azad university, arak branch, arak, iran mohammad alimoradi

department of chemistry, faculty of science islamic azad university, arak branch, arak, iran

چکیده

naphthol isomers were simultaneously and spectrophotometrically determined in wastewater, using a model based on net analyte signal (nas). the calibration method used is a variation of the original hybrid linear analysis method as proposed by goicoechea and olivieri (hla/go). owing to spectral interferences, the simultaneous determination of mixtures of naphthol isomers, using a spectrophotometric method, is difficult. a rapid and powerful method was used for wavelength selection in the modeling step, based on the minimization of the error indicator (ei), which was estimated as a function of the moving spectral region. the calculation of the net analytical signal using a modified hla/go method allows us to determine several figures of merit, as selectivity, sensitivity, analytical sensitivity and limit of detection of the proposed multivariate calibration. the limit of detection (lod) for 1 and 2-naphthol, were 0.04 and 0.06 (µg/ml) respectively. the proposed model was tested in the analysis of wastewater samples, without previous sample preparation steps, obtaining recovery values between 98 and 104.00%, for 1-naphthol and between 97.00 and 103.00%, for 2-naphthol.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Wavelength region selection and spectrophotometric simultaneous determination of naphthol isomers based on net analyte signal

Naphthol isomers were simultaneously and spectrophotometrically determined in wastewater, using a model based on net analyte signal (NAS). The calibration method used is a variation of the original hybrid linear analysis method as proposed by Goicoechea and Olivieri (HLA/GO). Owing to spectral interferences, the simultaneous determination of mixtures of naphthol isomers, using a spectrophotomet...

متن کامل

Resolving Spectra Overlapping Based on Net Analyte Signal for Simultaneous Spectrophotometric Determination of Fluoxetine and Sertraline

The net analyte signal standard addition method was used for simultaneous spectrophotometric determination of sertraline and fluoxetine in pharmaceutical preparations. The method combines the advantages of the standard addition method with the net analyte signal concept to enable the extraction of information about an analyte from the spectra of multi-component mixtures. This method uses full s...

متن کامل

resolving spectra overlapping based on net analyte signal for simultaneous spectrophotometric determination of fluoxetine and sertraline

the net analyte signal standard addition method was used for simultaneous spectrophotometric determination of sertraline and fluoxetine in pharmaceutical preparations. the method combines the advantages of the standard addition method with the net analyte signal concept to enable the extraction of information about an analyte from the spectra of multi-component mixtures. this method uses full s...

متن کامل

Net analyte signal based statistical quality control.

Net analyte signal statistical quality control (NAS-SQC) is a new methodology to perform multivariate product quality monitoring based on the net analyte signal approach. The main advantage of NAS-SQC is that the systematic variation in the product due to the analyte (or property) of interest is separated from the remaining systematic variation due to all other compounds in the matrix. This enh...

متن کامل

Spectrophotometric simultaneous determination of nickel, cobalt and copper by orthogonal signal correction–partial least squares

A method for the simultaneous spectrophotometric determination of nickel, cobalt and copper based on theformation of their complexes with 2-(2-Thiazolylazo)-p-Cresol (TAC) in micellar media of Triton X-100 isproposed. The absorbance spectra were recorded in the range of 500 to 800 nm. The linear concentrationrange for nickel, cobalt and copper in solution calibration sets were 0.05–1.80, 0.10–6...

متن کامل

Simultaneous spectrophotometric determination of glutethimide and barbiturates.

T HE POSSIBILITY OF DRUG intoxication frequently arises in patients admitted to the hospital in coma. Ingestion of salicylates by children and of barbiturates by adults are the most common causes. Since the introduction of glutethimide (2-ethyl-2-phenylglutarimide) in 1954, there have been increasing reports implicating this drug in drug intoxication. Since the clinical picture of glutethimide ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian chemical communication

جلد ۵، شماره Issue ۲. ۱۳۳-۲۶۷، صفحات ۲۵۷-۲۶۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023