background and aims. there are many edentulous people with severely resorbed residual ridges and non-resilient lining mucosa that are unable to tolerate occlusal forces during functional and parafunctional movements. lining the tissue surface of dentures with a flexible material can theoretically distribute and absorb forces with cushioning effect. the aim of this study was to evaluate the effect of a soft liner on stress levels in mandibular complete denture and its supporting structures by finite element analysis. materials and methods. a simplified 3-dimensional finite element model of relatively resorbed mandible, mucosa, denture and a soft liner was prepared. then the model, with and without soft liner, underwent normal vertical and lateral occlusal forces. the stresses were analyzed using the ansys 12 software. results. using the soft liner increased stress levels up to 18.5% and 30% in the cortical bone and mucosa, respectively, after vertical load was applied in the incisor region. application of bilateral vertical load on the molar area increased stress in cortical bone u to 44% and in the mucosa up to 29%. unilateral loading in the canine area increased stress level in the mucosa up to 63.5%. the highest stress was seen at denture base followed by the cortical bone. conclusion. use of soft liners increased stress in denture supporting structures. higher level of stress concentration was observed primarily in the denture base followed by the cortical bone.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Finite Element Analysis of Soft-lined Mandibular Complete Denture and its Supporting Structures

BACKGROUND AND AIMS There are many edentulous people with severely resorbed residual ridges and non-resilient lin-ing mucosa that are unable to tolerate occlusal forces during functional and parafunctional movements. Lining the tissue surface of dentures with a flexible material can theoretically distribute and absorb forces with cushioning effect. The aim of this study was to evaluate the effe...

متن کامل

Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis

Effect of pontic width on stress distribution in abutment teeth and their supporting structures by finite element analysis Dr. J. Ghanbarzadeh* - Dr. MR. Sabooni* - Dr. M. Keshavarz** * Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Mashhad University of Medical Sciences. ** Assistant Professor of Dental Prostheses Dept., Faculty of Dentistry, Kerman University of Medical...

متن کامل

A Technique to Guide and Measure the Reduction of a Processed Mandibular Complete Denture for Resilient Soft Liner

A resilient soft liner (RSL) has been used in processed complete dentures but controlling its thickness has always been a challenge because of uneven reduction of the denture’s intaglio surface. Use of a thermoplastic vacuum-formed template and an endodontic K-file, as guides, for the reduction of a processed mandibular complete denture to receive RSL is described in the present report. A proce...

متن کامل

Appropriate Loading Techniques in Finite Element Analysis of Underground Structures

Stability of underground structures is assessed by comparing rock strength with induced stresses resulted from ground stresses. Rock mass surrounding the opening may fail either by fracture or excessive deformation caused. Accurate calculation of induced stresses is therefore fundamental in the stability analysis of an opening. Although numerical methods, particularly finite element method, are...

متن کامل

the effectiveness of adding a supporting implant in stress distribution of long span fixed partial denture (3d finite element analysis)

background and aim of study: long span is seen in many clinical situations, treatment planning options of these cases are difficult and may require: fpd, rpd or isp. each option has its own disadvantages: mechanical, patient relief and cost respectively. this article will evaluate the stress distribution of another treatment option which is adding a single supporting implant to the fpd by using...

متن کامل

The Biomechanical Effect of Different Denture Base Materials on the Articular Disc in Complete Denture Wearers: A Finite Element Analysis

AIM The objective of the present study was to evaluate the effect of different denture base materials on the stress distribution in TMJ articular disc (AD) in complete denture wearers. MATERIAL AND METHODS A three dimensional Finite Element (FEA) models of an individual temporomandibular joint (TMJ) was built on the basis CT scan. The FEA model consisted of four parts: the condyle, the articu...