effect of field of view on detection of external root resorption in cone-beam computed tomography

نویسندگان

yaser safi

sahar ghaedsharaf

alireza aziz

sepanta hosseinpour

چکیده

introduction: conventional methods for diagnosis of external root resorption (err) are based on clinical findings and x-ray observations which are not appropriate for early diagnosis. the present study assessed the effect of different sizes and field of views (fovs) in the diagnosis of simulated external root resorption by cone-beam computed tomography (cbct). methods and materials: in this diagnostic in vitro trial, 100 human extracted mandibular central incisors were collected and marked in 3 apical, middle and coronal areas. cavities with different sizes were created in buccal and lingual surfaces of each area. following this procedure, cbct images were taken in 2 different 6 × 6 cm and 12 × 8 cm fovs with the same voxel size of 0.2 mm. absence or presence of cavities in cbct images were assigned by 3 radiologists and compared with gold standard results which were obtained by measurement of the size of cavities using a digital caliper. sensitivity and specificity values, positive predictive value (ppv) and negative predictive value (npv), a z value and kappa values were calculated and reported. results: amounts of sensitivity in 6 × 6 cm fov with voxel size of 0.2 mm for small, medium and large cavities were 95.93%, 96.03% and 97.1%, respectively. amounts of sensitivity in 12 × 8cm fov with the same voxel size for small, medium and large cavities were noted as 94.4%, 96.03% and 98.5%, respectively. however, specificity in fov of 6 × 6 cm and fov of 12 × 8 cm was calculated as 93.03% and 90.83%, respectively. conclusion: both used fovs show nearly same performances in the case of detection of err; therefore, smaller fov should be preferably used for detection of err in order to decrease the amount of imposed radiation dose given to patients.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

effect of voxel size on detection of external root resorption defects using cone beam computed tomography

conclusion considering the similar diagnostic efficacy of all voxel sizes, 300 µm voxel size can be used with adequate efficacy for detection of external root resorption defects with minimal patient radiation dose and the shortest scanning time. background selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed to...

متن کامل

Effect of Voxel Size on Detection of External Root Resorption Defects Using Cone Beam Computed Tomography

BACKGROUND Selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed tomography (CBCT) is particularly important. OBJECTIVES This study aimed to assess the effect of voxel size on detection accuracy of simulated external root resorption defects using NewTom CBCT system. MATERIALS AND METHODS In this diagnostic s...

متن کامل

Accuracy of digital periapical radiography and cone-beam computed tomography in detecting external root resorption

PURPOSE The purpose of this study was to evaluate and compare the efficacy of cone-beam computed tomography (CBCT) and digital intraoral radiography in diagnosing simulated small external root resorption cavities. MATERIALS AND METHODS Cavities were drilled in 159 roots using a small spherical bur at different root levels and on all surfaces. The teeth were imaged both with intraoral digital ...

متن کامل

In vitro comparison of cone beam computed tomography with different voxel sizes for detection of simulated external root resorption.

The present study compared the efficacy of cone beam computed tomography using different voxel sizes in the diagnosis of simulated external root resorption. The presence or absence of simulated defects on buccal, mesial and distal root surfaces of 20 premolars was evaluated. The defects were small (0.26 mm in diameter and 0.08 mm deep), medium (0.62 mm in diameter and 0.19 mm deep) and large (1...

متن کامل

Prevalence of Idiopathic Osteosclerosis on Cone Beam Computed Tomography Images

Objectives: This study was performed to investigate the prevalence of idiopathic osteosclerosis on cone beam computed tomography (CBCT) images of patients. Methods: In this descriptive, cross-sectional study, 240 CBCT scans of patients (125 women, 115 men) referred to a private oral and maxillofacial radiology clinic in Tehran in 2013 were selected and evaluated. Presence of idiopathic osteosc...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۱۲، شماره ۲، صفحات ۱۷۹-۱۸۴

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023