evaluating the effect of ceramic veneer thickness on degree of conversion in three luting resin cements

نویسندگان

nafiseh elmamooz assistant professor, oral and dental disease research center, kerman university of medical sciences, kerman, iran.

ali eskandarizadeh associate professor, oral and dental disease research center, kerman university of medical sciences, kerman, iran

elina rahmanian resident of operative dentistry, oral and dental disease research center, kerman university of medical sciences, kerman, iran

shahriar sarvareh azimzadeh resident of orthodontics, oral and dental disease research center, kerman university of medical sciences, kerman, iran

چکیده

compare the effect of different ceramic thicknesses on degree of conversion (dc) of 3 light-cured resin cements. methods: in this experimental in-vitro study, the degree of conversion of three light-cured resin cements, variolink veneer (ivoclar, liechtenstein), relyx veneer (3m espe, usa) and choice2 (bisco, usa) were evaluated beneath feldespatic ceramic discs (vita vmk master) with a same shade,  2m2, in different thicknesses (0.5, 1, 2 and3 mm) using ftir. the light curing unit used was optilux 501, with an intensity of 600 mw/cm2 and exposure duration of 40 seconds. three specimens of each cement group were examined in each condition. the obtained data was submitted to kolmogorov-smirnov and also checked for absence of skewness and kurtosis for normal distribution. after that, anova test was used for comparison between experimental groups (tukey hsd). results: in all the three used cements, dc decreased as ceramic thickness increased. this reduction was not significant when using 0.5 and 1 mm ceramic discs, however, it was significant between 1, 2, and 3mm discs(p<0.05). there was no difference within the cements’ dc when exposed through ceramic discs of 0.5, 1, and 2mm, but the rely x veneer cement had a lower dc compared to variolink veneer and choice2 when the thickness increased to 3mm(p<0.05). conclusion: it is not advisable to use light-cured resin cements beneath 3 mm thick ceramics and the use of rely x veneer is not recommended as the ceramic thickness increases.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluating the effect of ceramic veneer thickness on degree of conversion in three luting resin cements

compare the effect of different ceramic thicknesses on degree of conversion (DC) of 3 light-cured resin cements. Methods: In this experimental in-vitro study, the degree of conversion of three light-cured resin cements, Variolink Veneer (Ivoclar, Liechtenstein), RelyX Veneer (3M ESPE, USA) and Choice2 (Bisco, USA) were evaluated beneath feldespatic ceramic discs (Vita VMK Master) with a same sh...

متن کامل

the washback effect of discretepoint vs. integrative tests on the retention of content in knowledge tests

در این پایان نامه تاثیر دو نوع تست جزیی نگر و کلی نگر بر به یادسپاری محتوا ارزیابی شده که نتایج نشان دهندهکارایی تستهای کلی نگر بیشتر از سایر آزمونها است

15 صفحه اول

the effect of taftan pozzolan on the compressive strength of concrete in the environmental conditions of oman sea (chabahar port)

cement is an essential ingredient in the concrete buildings. for production of cement considerable amount of fossil fuel and electrical energy is consumed. on the other hand for generating one tone of portland cement, nearly one ton of carbon dioxide is released. it shows that 7 percent of the total released carbon dioxide in the world relates to the cement industry. considering ecological issu...

A critical analysis of the degree of conversion of resin-based luting cements

OBJECTIVE This study analyzed the degree of conversion (DC%) of four resin-based cements (All Ceram, Enforce, Rely X ARC and Variolink II) activated by two modes (chemical and dual), and evaluated the decrease of DC% in the dual mode promoted by the interposition of a 2.0-mm-thick IPS Empress 2 disc. MATERIAL AND METHODS In the chemical activation, the resin-based cements were prepared by mix...

متن کامل

the effect of e-64 on the developmental competence of sheep cocs during in vitro maturation

in the present study, the effect of e-64 at different concentrations (0.5, 1, 5 and 10 µm) added to (1) the ivm medium on oocyte nuclear maturation and developmental competence of ovine oocytes, and (2) to the ivc medium on embryonic development of ovine embryos were investigated.