diagnostic value of dual-source computerized tomography combined with perfusion imaging for peripheral pulmonary embolism

نویسندگان

xijin mao department of radiology, affiliated hospital of qingdao university, qingdao, china; department of radiology, affiliated hospital of binzhou medical college, binzhou, china

shanshan wang department of radiology, affiliated hospital of binzhou medical college, binzhou, china

xingyue jiang department of radiology, affiliated hospital of binzhou medical college, binzhou, china

lin zhang department of radiology, affiliated hospital of binzhou medical college, binzhou, china

چکیده

conclusion ped software of dual-source ct combined with perfusion imaging can significantly improve the detection rate of peripheral pulmonary embolism. results ctpa images revealed 50 (7.81%) segmental and 56 (4.38%) sub-segmental pulmonary embolisms, while the ped images showed 68 (10.63%) segmental and 94 (7.34%) sub-segmental pulmonary embolisms. thus, the detection rate on ped images for peripheral pulmonary embolism was significantly higher than that of the ctpa images (p < 0.05). there was good consistency for diagnosing segmental pulmonary embolism between ped and ctpa and depi (kappa = 0.85). the sensitivity and specificity of depi images for the diagnosis of pulmonary embolism were 91.7% and 97.5%, respectively. background pulmonary embolism has become the third most common cardiovascular disease, which can seriously harm human health. objectives to investigate the diagnostic value of dual-source computerized tomography (ct) and perfusion imaging for peripheral pulmonary embolism. patients and methods thirty-two patients with suspected pulmonary embolism underwent dual-source ct exams. to compare the ability of pulmonary embolism detection software (ped) with ct pulmonary angiography (ctpa) in determining the presence, numbers, and locations of pulmonary emboli, the subsequent images were reviewed by two radiologists using both imaging modalities. also, the diagnostic consistency between ped and ctpa images and dual-energy pulmonary perfusion imaging (depi) for segmental pulmonary embolism was compared.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Value of Dual-Source Computerized Tomography Combined with Perfusion Imaging for Peripheral Pulmonary Embolism

BACKGROUND Pulmonary embolism has become the third most common cardiovascular disease, which can seriously harm human health. OBJECTIVES To investigate the diagnostic value of dual-source computerized tomography (CT) and perfusion imaging for peripheral pulmonary embolism. PATIENTS AND METHODS Thirty-two patients with suspected pulmonary embolism underwent dual-source CT exams. To compare t...

متن کامل

Diagnostic value of Flash dual-source CT coronary artery imaging combined with dual-energy myocardial perfusion imaging for coronary heart disease

The present study aimed to investigate the diagnostic value of Flash dual-source CT coronary angiography (DS-CTA) combined with dual-energy myocardial perfusion imaging (DS-CTP) for coronary heart disease (CHD), as a single-stage examination. A total of 60 patients with CHD underwent DS-CT examination, as well as coronary angiography (CAG), as the reference standard. The patients were divided i...

متن کامل

Determination of Diagnostic Value of Albumin, Anti Thrombin Ш, and Fibrinogen Factors in the Diagnosis of Pulmonary Embolism Compared to Lung Perfusion Scan in Patients with Nephrotic Syndrome

Bachground: The aim of this study was to determine of diagnostic value of albumin, anti-thrombin Ш, and fibrinogen factors in the diagnosis of pulmonary embolism compared to lung perfusion scan in patients with nephrotic syndrome referred to Hazrat Ali Asghar hospital of Tehran city (Iran) in 2018-2019.  Methods: This study was cross sectional study that was carried out on 30 patients with nep...

متن کامل

Dynamic myocardial perfusion imaging by dual-source computed tomography.

We report a dual-source computed tomography study of dynamic and quantitative myocardial perfusion in a 44-year-old patient with previous documented coronary artery disease. Quantitatively, the tomography showed myocardial perfusion deficit in the territories with significant coronary stenosis, confirmed by computed tomography angiography and conventional angiography. Dual-source computed tomog...

متن کامل

Diagnostic Value of Ankle Brachial Index for Myocardial Ischemia in Asymptomatic Diabetic Patients and Comparison with Myocardial Perfusion Imaging

Objective: The ankle-brachial index (ABI) as a simple test which can detect peripheral arterial disease (PAD). Therefore in this study we try to evaluate the diagnostic value of ABI for silent myocardial ischemia in diabetic patients and compare the results with myocardial perfusion imaging (MPI) results. Materials and Methods: All 149 diabetic patients in this study were categorized according...

متن کامل

Diagnostic value of PET/CT for giant cell arteritis combined with pulmonary embolism presenting

RATIONALE Giant cell arteritis (GCA) combined with concomitant pulmonary embolism (PE) is extremely difficult to diagnose because of its low incidence and atypical clinical presentations. PATIENT CONCERNS A 62-year-old male developed fever of unknown origin. DIAGNOSES Positron emission tomography/computed tomography (PET/CT) revealed increased glucose metabolism in the vascular walls of the...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۱۳، شماره ۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023