agreement between panoramic and lateral cephalometric radiographs for measuring the gonial angle

نویسندگان

maryam zangouei-booshehri department of oral and maxillofacial radiology, faculty of dentistry, shahid sadoughi university of medical sciences, imam ave., daheye fajr blvd, iran +98-3516255881, [email protected]

hossein-agha aghili department of orthodontics, faculty of dentistry, shahid sadoughi university of medical sciences, iran

mojtaba abasi faculty of dentistry, shahid sadoughi university of medical sciences, iran

fatemeh ezoddini-ardakani department of oral and maxillofacial radiology, faculty of dentistry, shahid sadoughi university of medical sciences, imam ave., daheye fajr blvd, iran +98-3516255881, [email protected]; department of oral and maxillofacial radiology, faculty of dentistry, shahid sadoughi university of medical sciences, imam ave., daheye fajr blvd, iran +98-3516255881, [email protected]

چکیده

background the gonial angle is one of the most important measurements required for orthodontic treatment and orthognathic surgery. it is difficult to determine the accurate measurement of each gonial angle on cephalometric radiographs because of superimposition of the left and right angles. objectives the aim of the present study was to determine the right and left gonial angles on panoramic radiographs and to compare them with an evaluated cephalometric sample. patients and methods a total of 80 panoramic and 80 cephalometric radiographs were obtained from 6 to 12-year-old children and the gonial angle was determined by the tangent of the inferior border of the mandible and the most distal aspect of the ascending ramus and the condyleon both panoramic and cephalometric radiographs. we used pearson’s correlation coefficient and paired t-test for comparison. results the mean gonial angle was 127.07 ± 6.10 and 127.5 ± 6.67 degrees on panoramic and cephalometric radiographs, respectively. there was no statistically significant difference between the measured gonial angles on panoramic and cephalometric radiographs and also no difference between the right and left (both ps = 0.18) conclusion the value of the gonial angle measured on panoramic radiography was the same as that measured on the routinely used cephalometric radiography.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Agreement Between Panoramic and Lateral Cephalometric Radiographs for Measuring the Gonial Angle

BACKGROUND The gonial angle is one of the most important measurements required for orthodontic treatment and orthognathic surgery. It is difficult to determine the accurate measurement of each gonial angle on cephalometric radiographs because of superimposition of the left and right angles. OBJECTIVES The aim of the present study was to determine the right and left gonial angles on panoramic ...

متن کامل

Comparative analysis of the gonial angle on lateral cephalometric radiographs and panoramic radiographs.

We measured the gonial angle (GA) on panoramic radiography (PR) and analyzed the correlation between the GA on PR and lateral cephalometric radiography (LCR). In total, 49 PR films and LCR films from dentate young adults were evaluated. Orthodontists plotted four points (articulare, menton, posterior gonion, and lower gonion) on the PR and carefully traced them. Using a protractor, two radiolog...

متن کامل

Comparison between the external gonial angle in panoramic radiographs and lateral cephalograms of adult patients with Class I malocclusion.

The external gonial angle is an important angle of the craniofacial complex. It is significant for the diagnosis of craniofacial disorders. Lateral cephalogram and orthopantomograms can be used to determine this angle. In this study, we compared the external gonial angle determined from the two mentioned radiographs in Class I patients. We collected the radiographs of 70 patients with Angle's C...

متن کامل

Dilemma of gonial angle measurement: Panoramic radiograph or lateral cephalogram

PURPOSE The purpose of this study was to evaluate the accuracy of panoramic imaging in measuring the right and left gonial angles by comparing the measured angles with the angles determined using a lateral cephalogram of adult patients with class I malocclusion. MATERIALS AND METHODS The gonial angles of 50 class I malocclusion patients (25 males and 25 females; mean age: 23 years) were measu...

متن کامل

Accuracy of Assessment of Gonial Angle by Both Hemispheres of Panoramic Images and Its Comparison with Lateral Cephalometric Radiographic Measurements

Professor Yrjo Paatero, in 1961, first introduced the Orthopantomography (OPG) [1]. It has been extensively used in dentistry for analysing the number and type of teeth present, caries, impacted teeth, root resorption, ankylosis, shape of the condyles [2], temporomandibular joints, sinuses, fractures, cysts, tumours and alveolar bone level [3,4]. Panoramic radiography is advised to all patients...

متن کامل

بررسی میزان هماهنگی بین اندازه گیری های انجام شده توسط رادیوگرافی پانورامیک و سفالومتری جانبی در تشخیص الگوی رشد عمودی صورت

Background & Aims: One of the most important issues in training, diagnosis, and treatment in orthodontics is a thorough understanding of patient’s growth pattern. Imbalances in this pattern can cause malocclusion which is one of the most important causes of referring patients for treatment. At the first step, dentist’s responsibility is the diagnosis and monitoring of the growth pat...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۹، شماره ۴، صفحات ۱۷۸-۸۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023