an evaluation of the flexural properties of meliodent and acropars heat polymerized acrylic resins

نویسندگان

f. golbidi

o. jalali

چکیده

objective: the aim of this study was to measure and compare the transverse strength and deflection of two acrylic resins. method and materials: a total of 30 samples, with dimensions of 2.5×10×65mm, were prepared with acropars and meliodent acrylic resins according to ada specification no. 12. the specimens were divided into two groups of 15 samples each. a three-point bending test was carried out using a universal testing machine. differences between the means of the two groups were analyzed with student's t -test. results: the mean (sd) transverse strength was 81.55 (1.54) mpa in the meliodent and 73.58 (0.6) mpa in the acropars samples, which showed a significant difference (p<0.001). the mean (sd) transverse deflection was 3.86 (0.09) mm and 4.96 (0.06) mm in the meliodent and acropars samples, respectively. a significant difference was found between the two groups (p<0.001). conclusion: in the present investigation, the transverse strength of the acropars specimens was smaller than that of the meliodent samples and ada specifications. however, the mean transverse deflection was larger in the acropars group as compared to the meliodent group.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of the impact strength between Acropars and Meliodent acrylic resins

A comparison of the impact strength between Acropars and Meliodent acrylic resins Dr. F. Golbidi* - Dr. A. Meghdadi** *-Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry – Isfahan University of Medical Sciences. **-Dentist. Background and Aim: One of the mostly used materials in removable prostheses are acrylic resins with various physical and mechanical properties. The impact ...

متن کامل

Flexural Strength of Acrylic Resins Polymerized by Different Cycles

Despite the large number of studies addressing the effect of microwave polymerization on the properties of acrylic resin, this method has received limited clinical acceptance. This study evaluated the influence of microwave polymerization on the flexural strength of a denture base resin. A conventional heat-polymerized (Clássico), a microwave-polymerized (Onda-Cryl) and a autopolymerizing acryl...

متن کامل

Water Sorption and Flexural Strength of Thermoplastic and Conventional Heat-Polymerized Acrylic Resins

OBJECTIVES The aim of this study was to assess and compare the water sorption and flexural strength of thermoplastic and conventional acrylic resins. MATERIALS AND METHODS Water sorption and flexural strength were compared between a thermoplastic modified polymethyl methacrylate (PMMA) denture base resin (group A) and a heat-polymerized PMMA acrylic resin (group B) as the control group (n=10)...

متن کامل

water sorption and flexural strength of thermoplastic and conventional heat-polymerized acrylic resins

objectives: the aim of this study was to assess and compare the water sorption and flexural strength of thermoplastic and conventional acrylic resins. materials and methods: water sorption and flexural strength were compared between a thermoplastic modified polymethyl methacrylate (pmma) denture base resin (group a) and a heat-polymerized pmma acrylic resin (group b) as the control group (n=10)...

متن کامل

Comparative Evaluation of the Flexural Strength of Heat Polymerized Acrylic Resin with the Addition of 8% and 13% Aluminum Oxide Powder: An In-vitro Study

Introduction: Acrylic resins have been used successfully as denture bases. However, acrylic resin denture base materials are brittle and have poor strength and thermal conductivity. Therefore, it is essential to improve the flexural strength of heat polymerized acrylic resin. The present study aimed to evaluate and compare the flexural strength of heated polymerized acrylic res...

متن کامل

Assessment of flexural strength and color alteration of heat-polymerized acrylic resins after simulated use of denture cleansers.

The purpose of this study was to assess flexural strength and color alteration of acrylic resins immersed in denture cleansers for different periods of time. Rectangular specimens (65 x 10 x 3mm) made from three heat-polymerized acrylic resins (Lucitone 550, QC-20 and Triplex) were assigned to three denture cleansers groups (Bony Plus, Corega Tabs and Efferdent Plus) and a control group (immers...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of dentistry, tehran university of medical sciences

جلد ۴، شماره ۲، صفحات ۶۸-۷۱

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023