external radiation dose from patients received diagnostic doses of ²º¹tl-chloride and 99mtc-mibi [persian]

نویسندگان

simin dadashzadeh

golahmad nasiroghli

ali sattari

چکیده

patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. therefore, the measurement of external radiation dose from these patients is necessary. in this study, the dose rates at distances of 10, 50 and 100cm from 70 patients who received diagnostic amounts of ²º¹tl-chloride and 99mtc-mibi was measured. the results showed that the maximum external radiation dose rates for ²º¹tl and 99mtc were 18.4 and 75.0 μsv.h^-1, respectively, at 5 cm distance from the patients. the average radiation dose received by nuclear medicine technologists, considering their close contact during one working day was 12.5±3.4 μsv. the highest received dose was 22.7 μsv, which was well below the acceptable dose limit.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

External radiation dose from patients received diagnostic doses of ²º¹Tl-Chloride and 99mTc-MIBI [Persian]

Patients receiving diagnostic doses of radiopharmaceuticals become a source of contamination and exposure for those who come in contact with them, such as nuclear medicine technologists, relatives and nurses. Therefore, the measurement of external radiation dose from these patients is necessary. In this study, the dose rates at distances of 10, 50 and 100cm from 70 patients who received d...

متن کامل

Radiation dose to the nuclear medicine nurses

Background: People who have been administrated radiopharmaceuticals could be a source of radiation to their relatives, medical nurses, and people who are in contact with them. The aim of this work was to estimate radiation dose received by nuclear medicine nurses. Materials and Methods: In this study, the dose rates at various distances of 5 – 100 cm from 70 patients, who were administered diag...

متن کامل

Iranian physicians\' knowledge about radiation dose, received by patients in diagnostic radiology

Background: Although ionizing radiation is widely used to diagnose many diseases, the relevant hazards are known to be as an important limitation of its application. It is believed that the awareness of ionizing radiation dose values is one of the main stages in patient's radiation protection. The purpose of this study has been to investigate the level of physicians' knowledge about radiation d...

متن کامل

99mTc-MIBI scintigraphy in musculoskeletal tumors [Persian]

The aim of this study was to assess the value of 99mTc-hexakis-2-methoxyisobutylisonitrile (MIBI) scintigraphy in patients with clinical and radiologic features of primary or metastatic musculoskeletal tumors. Methods: The scintigraphic findings for 84 patients were compared with the surgical and histologic findings. Each patient underwent three-phase bone scan with 99mTc-methylene diphos...

متن کامل

Comparison of brain SPECT with 99mTc-MIBI and CT-scan in discriminating of radiation necrosis and brain tumor recurrence [Persian]

Introduction: 99mTc-MIBI has been proposed for use as an imaging agent for various tumors, including breast cancer, lung cancer, lymphomas, melanomas and brain neoplastic lesions. Brain tumors are very common and radiotherapy being major part of treatment following surgery. After radiotherapy, deteriorating clinical status can be due to either radiation necrosis or recurrent tumor. Comput...

متن کامل

Film Reject Analysis and Radiation Doses Received by Patients in Selected Hospitals in Southwestern Nigeria

Introduction: A reject rate is the percentage of diagnostic images repeated due to errors during radiological examinations. The present study aimed to evaluate the patient radiation doses and analyze the film reject rate as part of quality assurance program in three diagnostic centers in Nigeria. Materials and Methods: This study was conducted in three hospitals, namely Federal Medical Center ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of nuclear medicine

ناشر: tehran university of medical sciences

ISSN 1681-2824

دوره 10

شماره 1 2002

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023