the importance of shimming in magnetic resonance spectroscopy

نویسندگان

reza faghihi

mohammad amin mosleh-shirazi

reza jalli shiraz university of medical sciences, shiraz, iran

sedigheh sina

چکیده

conclusions by a simple check of the water peak characteristics, lots of information can be obtained, one of which is the status of shimming that has a considerable effect on the accuracy of the spectrum. thus, performing an automatic or manual shimming is not a criterion of the spectrum accuracy, and performing a periodic quality control using a test phantom by a specialist is necessary. briefly, the quality control of mrs and all the other clinical device must be taken seriously. sometimes qc can be the boundary of a right or a wrong decision for the patient. results the spectrum of our home- made phantom had a significant difference with the expected spectrum. the results of checking the spectrum of metabolites separately also confirmed that there was a systemic problem that affects all the signals originated from all metabolites and even the pure distilled water. the mrs system could not pass qc tests, and peak broadening was common in all spectra. the complex spectrum of standard test phantom was not produced successfully by the mrs system. methods an acrylic cylindrical quality control phantom was designed as an analog of brain mrs test phantoms in order to control the accuracy of the obtained signal of a 1.5 t siemens mri system which belonged to one of shiraz hospitals. the signal of naa, cho, cr, the combination of these metabolites and also the distilled water, which was used in this study, was evaluated using separate phantoms. a qc test was performed using siemens qc phantom and a standard test phantom. background proton magnetic resonance spectroscopy (mrs) is a well-known device for analyzing the biological fluids metabolically. obtaining accurate and reliable information via mrs needs a homogeneous magnetic field in order to provide well-defined peaks and uniform water suppression. there are lots of reasons which can disturb the magnetic field homogeneity which can be corrected by a process known as shimming. this study is intended to recall the importance of shimming and also the significant role of quality control (qc) in achieving an accurate quantification.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

B0 magnetic field homogeneity and shimming for in vivo magnetic resonance spectroscopy.

The homogenization of B0 conditions is necessary for every magnetic resonance spectroscopy (MRS) investigation. Its direct consequence is narrow spectral lines, on which reliable separation and quantification of biochemicals, and thus experimentally obtainable metabolic information, fundamentally relies. Besides spectral linewidth, unwanted B0 inhomogeneity also impairs other aspects of the MRS...

متن کامل

Structural shimming for high-resolution nuclear magnetic resonance spectroscopy in lab-on-a-chip devices.

High-resolution proton NMR spectroscopy is well-established as a tool for metabolomic analysis of biological fluids at the macro scale. Its full potential has, however, not been realised yet in the context of microfluidic devices. While microfabricated NMR detectors offer substantial gains in sensitivity, limited spectral resolution resulting from mismatches in the magnetic susceptibility of th...

متن کامل

Application of magnetic resonance spectroscopy for evaluating metabolic alteration in anterior cingulate cortex in Alzheimer's disease

Introduction: Alzheimer’s disease (AD) is the most common cause of dementia worldwide. Mild cognitive impairment (MCI) is often the prodromal stage to AD. Most patients with MCI harbor the pathologic changes of AD and demonstrate transition to AD at a rate of 10–15% per year. Accumulating evidence indicates that the asymmetry changes of left and right brain have happened in the early stage of A...

متن کامل

Application of Magnetic Resonance Spectroscopy in Neurocognitive Assessment After Head Injury: A Systematic Review

Background: Traumatic brain injury is believed to be a public health disorder with some complications. Post Traumatic Neurocognitive Disorders (PTND) received much attention among these complications because of the high prevalence of mild traumatic brain injuries. On the other hand, advanced neuroimaging is increasingly becoming an exciting modality in the field of traumatic brain injury. Magne...

متن کامل

Detection of Glioblastoma Multiforme Tumor in Magnetic Resonance Spectroscopy Based on Support Vector Machine

Introduction: The brain tumor is an abnormal growth of tissue in the brain, which is one of the most important challenges in neurology. Brain tumors have different types. Some brain tumors are benign and some brain tumors are cancerous and malignant. Glioblastoma Multiforme (GBM) is the most common and deadliest malignant brain tumor in adults. The average survival rate for peo...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of radiology

جلد ۲۰۱۷، شماره ۵، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023