mitral valve prolapse classification from an echocardiography sequence using coherent point drift method based on fractal dimension

نویسندگان

m siyah mansoory

p moradi birgani

m ashtiani

a khorrami moghaddam

چکیده

background: mitral valve prolapse (mvp) is now recognized as the most common cardiovalvular abnormality (cva) in the usa, but there has been much less agreement about other aspects of its epidemiology, diagnosis and clinical features. cva analysis still relies mainly on the visual assessment of echocardiographic imaging and manual measurements by experienced cardiologists. so, automating or semi-automating analysis of echocardiographic images for mvp detection is, therefore, highly desirable, but also challenging due to low image quality and high amount of speckle noise. objective: the main objective of this paper was to test the hypothesis that fractal dimension (fd) values are significantly higher in severe mvp and moderate mvp cases than those of healthy subjects in motion pattern of their mitral valves. materials and methods: in this paper, we present a noninvasive algorithm that does not require any segmentation. this approach has three steps: first, we extracted corners as landmarks from echocardiographic sequences based on susan corner detector. then, landmarks were tracked using coherent point drift (cpd) non-rigid registration. after that, the motion patterns of the landmarks were analyzed to extract features (fd) in order to classify the mitral valve behavior of 46 patients and 25 normals as normal, moderate or severe mvp. results: the results show that moderate mvp detection has a relatively good sensitivity (82%) and specificity (82%). conclusion: the motion pattern of landmarks in mvp patients, obtained by cpd method, differed from that of normals in such a way that the difference can be quantified and analyzed by fd.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Marcus-gunn phenomenon with- mitral valve prolapse

Marcus-gunn phenomenon is a congenital and sometimes hereditary anomaly, in which a ptotic eyelid retracts momentarily when the mouth is open, or the jaw is moved. These associated movements attributed to abnormal connections between the central mechanisms innervating the pterygoid and elevator muscles. Sometimes this anomaly is associated with dual,s retraction syndrome, duplex kindneys and ur...

متن کامل

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

An Adaptive Segmentation Method Using Fractal Dimension and Wavelet Transform

In analyzing a signal, especially a non-stationary signal, it is often necessary the desired signal to be segmented into small epochs. Segmentation can be performed by splitting the signal at time instances where signal amplitude or frequency change. In this paper, the signal is initially decomposed into signals with different frequency bands using wavelet transform. Then, fractal dimension of ...

متن کامل

An Adaptive Segmentation Method Using Fractal Dimension and Wavelet Transform

In analyzing a signal, especially a non-stationary signal, it is often necessary the desired signal to be segmented into small epochs. Segmentation can be performed by splitting the signal at time instances where signal amplitude or frequency change. In this paper, the signal is initially decomposed into signals with different frequency bands using wavelet transform. Then, fractal dimension of ...

متن کامل

Mitral-valve repair for mitral-valve prolapse.

n engl j med 361;23 nejm.org december 3, 2009 2261 This Journal feature begins with a case vignette that includes a therapeutic recommendation. A discussion of the clinical problem and the mechanism of benefit of this form of therapy follows. Major clinical studies, the clinical use of this therapy, and potential adverse effects are reviewed. Relevant formal guidelines, if they exist, are prese...

متن کامل

Mitral valve prolapse: role of 3D echocardiography in diagnosis.

PURPOSE OF REVIEW To review the utility and the latest developments in three-dimensional (3D) echocardiography of mitral valve prolapse. RECENT FINDINGS Although 3D echocardiography was invented in 1974, it did not gain wide clinical acceptance until the introduction of real-time 3D echocardiography in the first decade of the 21st century. Driven by improvements in probe technology and increa...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of biomedical physics and engineering

جلد ۲۰۱۲، شماره ۱۲، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023