tissue reaction and biocompatibility of implanted mineral trioxide aggregate with silver nanoparticles in a rat model

نویسندگان

vahid zand

mehrdad lotfi

amirala aghbali

mehran mesgariabbasi

چکیده

introduction: biocompatibility and antimicrobial activity of endodontic materials are of utmost importance. considering the extensive applications of mineral trioxide aggregate (mta) in dentistry and antimicrobial properties of silver nanoparticles, this study aimed to evaluate the subcutaneous inflammatory reaction of rat connective tissues to white mta with and without nanosilver (ns) particles. methods and materials: polyethylene tubes (1.1×8 mm) containing experimental materials (mta and mta+ns and empty control tubes) were implanted in subcutaneous tissues of seventy-five male rats. animals were divided into five groups ( n =15) according to the time of evaluation: group 1; after 7 days, group 2; after 15 days, group 3; after 30 days, group 4; after 60 days and group 5; after 90 days. the inflammatory reaction was graded and data was analyzed using the kruskal-wallis and mann-whitney u tests. statistical significance was defined at 0.05. results: comparison of cumulative inflammatory reaction at all intervals revealed that the mean grade of inflammatory reaction to mta, mta+ns and control samples were 3, 2 and 2, respectively. according to the mann-whitney analysis there were no significant differences between mta+ns and mta ( p =0.42). conclusion: incorporation of 1% nanosilver to mta does not affect the inflammatory reaction of subcutaneous tissue in rat models.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tissue Reaction and Biocompatibility of Implanted Mineral Trioxide Aggregate with Silver Nanoparticles in a Rat Model

INTRODUCTION Biocompatibility and antimicrobial activity of endodontic materials are of utmost importance. Considering the extensive applications of mineral trioxide aggregate (MTA) in dentistry and antimicrobial properties of silver nanoparticles, this study aimed to evaluate the subcutaneous inflammatory reaction of rat connective tissues to white MTA with and without nanosilver (NS) particle...

متن کامل

Reaction of rat connective tissue to implanted dentin tubes filled with a white mineral trioxide aggregate.

The purpose of this paper was to study the reaction of rat subcutaneous connective tissue to the implantation of dentin tubes filled with white mineral trioxide aggregate (MTA), a material that will be marketed. The tubes were implanted into rat subcutaneous tissue and the animals were sacrificed after 7 and 30 days. The undecalcified pieces were prepared for histological analysis with polarize...

متن کامل

Zeolite-silver-zinc nanoparticles: Biocompatibility and their effect on the compressive strength of mineral trioxide aggregate

BACKGROUND This study was carried out to evaluate the biocompatibility of zeolite-silver-zinc (Ze-Ag-Zn) nanoparticles and their effect on the compressive strength of Mineral Trioxide Aggregate (MTA). MATERIAL AND METHODS Biocompatibility was evaluated by an MTT assay on the pulmonary adenocarcinoma cells with 0.05, 0.1, 0.25, 0.5, 1 and 5 mg/mL concentrations of Ze-Ag-Zn. For compressive str...

متن کامل

Biocompatibility of Mineral Trioxide Aggregate with TiO2 Nanoparticles on Human Gingival Fibroblasts

BACKGROUND The New compositions of white mineral trioxide aggregate (WMTA) or use of various additives like nanoparticles might affect MTA's ideal characteristics This study was performed to evaluate the cytotoxicity of WMTA and WMTA with Titanium dioxide (TiO2) nanoparticles (1% weight ratio) at different storage times after mixing on human gingival fibroblasts (HGFs). MATERIAL AND METHODS H...

متن کامل

Reaction of rat connective tissue to mineral trioxide aggregate and diaket

BACKGROUND The aim of this study was to compare the reaction of rat connective tissue to two root-end filling materials: white Mineral Trioxide Aggregate (WMTA) and Diaket. METHODS Each of the materials was placed in dentine tubes and implanted subcutaneously in the dorsal connective tissue of 21 Wistar albino rats. Tissue biopsies were collected 7, 30, and 60 days after the implantation proc...

متن کامل

Evaluation of the rat tissue reaction to experimental new resin cement and mineral trioxide aggregate cement

OBJECTIVES New resin cement (NRC) has been developed as a root repairing material and the material is composed of organic resin matrix and inorganic powders. The aim of this study was to compare the rat subcutaneous tissue response to NRC and mineral trioxide aggregate (MTA) cement and to investigate the tissue toxicity of both materials. MATERIALS AND METHODS Sixty rats received two polyethy...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۱۱، شماره ۱، صفحات ۱۳-۱۶

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023