comparison of cleaning efficacy and instrumentation time in primary molars: mtwo rotary instruments vs. hand k-files

نویسندگان

fatemeh ramezanali

farzaneh afkhami

ali soleimani

mohammad javad kharrazifard

چکیده

introduction: pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand k-files and mtwo rotary system for preparation of human primary molars. methods and materials: this experimental study was conducted on 100 extracted primary maxillary and mandibular intact molars with no resorption. access cavities were prepared and india ink was injected into the root canal on a vibrator using an insulin syringe. canals were then divided into 5 groups ( n =20): in group i , canals were instrumented using k-files up to #25 for mesial and buccal canals and #30 for palatal and distal canals. in group ii , canals were prepared using mtwo rotary files (15/0.05, 20/0.06 and 25/0.06 for mesial and buccal canals and 15/0.05, 20/0.06, 25/0.06 and finally 30/0.05 for distal and palatal canals). in group iii , root canals were only irrigated with saline. groups iv and v were the positive and negative control groups, respectively. the time required for cleaning and preparation of the canals for each of the specimens in groups i, ii and iii was recorded. results: the mean score of cleanliness of mtwo was not significantly different from k-file group ( p >0.05). however the mean instrumentation time in mtwo group was significantly shorter ( p <0.001). conclusion: although there were no differences regarding the cleaning efficacy of either system, mtwo rotary files were far more time efficient.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Cleaning Efficacy and Instrumentation Time in Primary Molars: Mtwo Rotary Instruments vs. Hand K-Files

INTRODUCTION Pulpectomy is the preferred treatment for restorable primary teeth with symptomatic irreversible pulpitis or periradicular lesion. Considering the rather new application of rotary files for pulpectomy of primary teeth, the aim of this study was to compare the cleaning efficacy and instrumentation time of hand K-files and Mtwo rotary system for preparation of human primary molars. ...

متن کامل

Comparison of Cleaning Efficacy and Instrumentation Time of Reciproc and Mtwo Rotary Systems in Primary Molars

Background and Aim: Pulpectomy of primary teeth is commonly performed with hand files and instruments. However, it is a time consuming procedure. Compared to hand files, rotary instrumentation has more advantages. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous mo-lars using Reciproc and Mtwo rotary systems. Materials an...

متن کامل

root canal cleaning efficacy of rotary and hand files instrumentation in primary molars

introduction: pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. the purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand k-files and flex master rotary system. materials and methods: in this study, 68 canals of 23 extracted primary molars with a...

متن کامل

Root Canal Cleaning Efficacy of Rotary and Hand Files Instrumentation in Primary Molars

INTRODUCTION Pulpectomy of primary teeth is commonly carried out with hand files and broaches; a tricky and time consuming procedure. The purpose of this in vitro study was to compare the cleaning efficacy and time taken for instrumentation of deciduous molars using hand K-files and Flex Master rotary system. MATERIALS AND METHODS In this study, 68 canals of 23 extracted primary molars with a...

متن کامل

Assessment of cleaning efficacy of Mtwo NiTi rotary files and Hand K-files: A comparative in-vitro study

NTRODUCTION The goals of root canal therapy are to remove infected and necrotic pulpal tissue remnants, shape the root canal system to facilitate irrigation and medication and adequate sealing using obturation materials. 1 Rotary instruments enhance the quality of obturation by providing conical shape to the root canal. Nickle titanium (NiTi) alloy instruments inherent flexibility that allows t...

متن کامل

A COMPARISON OF Ni-Ti ROTARY AND HAND FILES INSTRUMENTATION IN PRIMARY MOLARS

The aim of the study was to compare the manual and rotary endodontic instruments focusing on risk of perforation when the whole root canal length is instrumented as well as the time required for preparation in primary teeth Fifty four teeth were divided randomly into three groups.Group I: The root canals were prepared manually with K-files. Group II : ProTaper instruments were used in a crown-d...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian endodontic journal

جلد ۱۰، شماره ۴، صفحات ۲۴۰-۲۴۳

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023