evaluation and comparing rectum and bladder's clinical complications in pelvis radiotherapy in order to treat prostate cancer by using custom block and mlc for three- dimensional conformal radiotherapy

نویسندگان

sadegh sabzi radiology technology department, faculty of paramedical sciences,shahid beheshti university of medical sciences,tehran,iran

mohsen bakhshandeh radiology technology department, faculty of paramedical sciences,shahid beheshti university of medical sciences,tehran,iran

mohammad houshyari radiation oncology department, hospital shohada tajrish, tehran,iran

nezhat shakeri department of biostatistics, faculty of paramedical sciences,shahid beheshti university of medical sciences,tehran,iran

چکیده

ionization radiation caused to incidence of complications in the exposed organs. in prostate radiotherapy, rectum and bladder have been radiated unwantedly and indicated some complications during and after treatment. the purpose of present study is to consider and to compare clinical complications of rectum and bladder in custom block and mlc for 3- d conformal radiotherapy, in order to determine if both treatments differ with respect to creating radiation protection, subsequently in the incidence of complications. in this respect, 72 patients with prostate cancer classified into two arms, above 60 years without the history of previous radiotherapy, hormone therapy and surgery, were selected randomly in october 2014. in one arm, patients were treated with block 3- d conformal radiotherapy, and in second arm with mlc outbound technique for 3- d radiotherapy. rectal and bladder clinical complications were recorded before, during (at the end of 10 treatment sessions), 3 and 6 months after treatment then compared based on tables (rtog/ lent).obtained results showed that patients had a significant difference in such complications as urinary frequency after 10 treatment sessions, 3 months after treatment (p<0.02 and p<0.04, respectively)   also, patients had a significant difference in regard to dysuria at the end of treatment (p<0.02). in both arms, patients had a significant difference in constipation after 30 sessions also at the end of treatment (p<0.02, p<0.02, respectively).in comparing different grades of complications based on rtog/ lent tables, it was not observed a significant difference between patients' complications in both arms.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-Dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: Dosimetric and radiobiologic analysis

 Background: To analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (IMRT) and 3 dimensional conformal radiotherapy (3DCRT) and selection of optimal photon energy for IMRT treatments. Material and methods: 24 patients with localized prostate carcinoma were planned for 3DCRT and IMRT techniques. Radiation dose of 54 Gy with 2 Gy/fraction, was planned to ...

متن کامل

3-dimensional conformal radiotherapy versus intensity modulated radiotherapy for localized prostate cancer: dosimetric and radiobiologic analysis

background: to analyze the dosimetric and radio biologic advantages between intensity modulated radiotherapy (imrt) and 3 dimensional conformal radiotherapy (3dcrt) and selection of optimal photon energy for imrt treatments. material and methods: 24 patients with localized prostate carcinoma were planned for 3dcrt and imrt techniques. radiation dose of 54 gy with 2 gy/fraction, was planned to p...

متن کامل

Dosimetric comparison between intensity modulated radiotherapy and three dimensional conformal radiotherapy planning in patients with locally advanced cervical carcinoma

Background: External beam radiotherapy (EBRT) is mainstay of treatment in patients with locally advanced cervical carcinoma (LACC). Three dimensional conformal radiotherapy (3DCRT) and intensity modulated radiotherapy (IMRT) are mainly used in EBRT. However which one is superior is still controversial. Materials and Methods: Forty patients of LACC treated with IMRT were selected for this study....

متن کامل

Dosimetry evaluation of salivary glands in 3D conformal radiotherapy and intensity modulated radiotherapy in oral tongue cancer

Introduction: The purpose of this study was to evaluate the dosimetric and radiobiological parameters of salivary glands in treatment of patients with oral tongue cancer by 3D conventional radiotherapy (3D-CRT) and intensity modulated radiation therapy (IMRT) techniques. Materials and Methods: This study was performed on treatment planning of patients with oral tongue cancer in T2-3/N0 cancer s...

متن کامل

Dosimetric comparison of whole breast radiotherapy using field in field and conformal radiotherapy techniques in early stage breast cancer

Background: We aimed to compare field-in-field technique (FIF) with conformal tangential field radiotherapy (CRT) in terms of dosimetric benefits for early stage breast cancer radiotherapy. Materials and Methods: Twenty consecutive left-side breast cancer patients who underwent breast-conserving surgery were included to the study. For each patient, two different treatment plans were cr...

متن کامل

Effect of Bolus Frequency and Its Thickness in Postmastectomy Three-dimensional Conformal Radiotherapy on Skin Dose for Superposition Algorithm

Introduction: The postmastectomy radiotherapy uses bolus to improve the coverage close to the skin; however, it needs to be removed in case of severe skin toxicity. This study investigated the effect of bolus parameters (i.e., frequency and thickness) for the superposition algorithm on skin dose in postmastectomy three-dimensional conformal radiotherapy (3D-CRT). <str...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of paramedical sciences

جلد ۷، شماره ۴، صفحات ۲۱-۲۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023