fibrosis evaluation by transient elastography in patients with long-term sustained hcv clearance

نویسندگان

vincenza calvaruso gastroenterologia and epatologia, di.bi.m.i.s., university of palermo, palermo, italy; gastroenterologia and epatologia, di.bi.m.i.s., university of palermo, piazza delle cliniche n.2, 90127 palermo, italy. tel: +39-916552280, fax: +39-916552156

vito di marco gastroenterologia and epatologia, di.bi.m.i.s., university of palermo, palermo, italy

donatella ferraro dipartimento di igiene g.d’alessandro, university of palermo, palermo, italy

salvatore petta gastroenterologia and epatologia, di.bi.m.i.s., university of palermo, palermo, italy

چکیده

background reversibility of advanced fibrosis after hcv-clearance is an important goal of therapy. objectives measuring liver stiffness (ls) by transient elastography (te) might be helpful in this setting. patients and methods we evaluated 104 patients with biopsy-proven chronic hepatitis c (chc) and sustained virological response (svr) after peg-interferon (ifn) plus ribavirin since at least 18 months. hcv-eradication was confirmed searching for serum hcv-rna (tma® sensitivity > 5-10 iu/ml). data from literature reported the best ls cut-off values for different stages of liver fibrosis were 7.1 kpa for metavir stage 2 (f2), 9.5 kpa for f3 and 12.5 for cirrhosis (f4). results te was not reliable in four svr obese patients. metavir-stage of biopsy was f0-1 in 28, f2 in 47, f3 in 17 and f4 in eight patients. the median interval elapsed since achieving svr was 36 months (range: 18-77, sd¬¬:18). stratifying patients according to the histological stage assessed before treatment, a clear-cut gradient of ls values was observed from f0-1: median: 3.8 kpa (range: 3.5-4.9) to f2: 4.6 kpa (3.8-6.0), f3: 6.2 kpa (4.8-8.6) and f4: 8.4 kpa (6.2-9.2) (p = 0.001). overall, 86 patients had lower values of ls than the expected ls values according to metavir-stage. at multivariate logistic analysis γ-gt and histological steatosis were independently associated with persistence of higher values of ls. conclusion long term responders to ifn-based therapies have lower ls values than those who are untreated and still viraemic. high levels of γ-gt and liver steatosis, all markers of insulin resistance, may hamper reduction of liver stiffness after hcv-clearance.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fibrosis Evaluation by Transient Elastography in Patients With Long-Term Sustained HCV Clearance

BACKGROUND Reversibility of advanced fibrosis after HCV-clearance is an important goal of therapy. OBJECTIVES Measuring liver stiffness (LS) by transient elastography (TE) might be helpful in this setting. PATIENTS AND METHODS We evaluated 104 patients with biopsy-proven chronic hepatitis C (CHC) and sustained virological response (SVR) after Peg-Interferon (IFN) plus ribavirin since at lea...

متن کامل

Assessment of hepatic fibrosis by transient elastography in rheumatoid arthritis patients receiving methotrexate

Background and Aim: Methotrexate (MTX) is commonly used in the treatment of diseases such as rheumatoid arthritis (RA) but, its hepatotoxicity potential, always has been a major concern. The aim of this study is to determine the rate of liver fibrosis by transient elastography (TE) method and its relationship with cumulative dose of MTX and duration of treatment, in rheumatoid arthritis patient...

متن کامل

Acoustic Radiation Force Impulse (ARFI) and Transient Elastography (TE) for evaluation of liver fibrosis in HIV-HCV co-infected patients

BACKGROUND Transient elastography (TE) is widely used for non-invasive assessment of liver fibrosis in HIV-HCV co-infected patients. TE, however, cannot determine liver morphology. Acoustic radiation force impulse (ARFI) imaging is a novel procedure enabling assessment of liver fibrosis during a conventional ultrasonographic examination. This study evaluated the correlation between liver fibros...

متن کامل

Evaluation of liver fibrosis by transient elastography in methotrexate treated patients.

BACKGROUND AND AIMS Methotrexate (MTX) safety is questioned by the risk of inducing liver fibrosis (LF). As transient elastography (FibroScan®) is an effective non-invasive technique to evaluate LF, our aims were to assess LF in MTX-treated patients, to evaluate LF regarding treatment duration and cumulative dose, and to determine differences depending on the underlying disease. PATIENTS AND ...

متن کامل

evaluating liver fibrosis by transient elastometry in patients with hiv-hcv coinfection and monoinfection

conclusions hcv coinfection, older age and ast were associated with lf in patients with hiv infection. objectives the aim of this cross-sectional study was to identify factors associated with liver fibrosis (lf) in patients with hiv monoinfection and hiv-hcv coinfection. patients and methods we analyzed lf by transient elastometry ([te], fibroscan) in three groups of patients (hiv, hiv-hcv and ...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
hepatitis monthly

جلد ۱۳، شماره ۵، صفحات ۰-۰

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023