assessment of an unshielded electron field diode dosimeter for beam scanning in small- to medium-sized 6 mv photon fields

نویسندگان

mohammad amin mosleh-shirazi 1- center for research in medical physics and biomedical engineering, shiraz university of medical sciences, shiraz, iran 2- physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran

sareh karbasi physics unit, department of radiotherapy and oncology, namazi hospital, shiraz university of medical sciences, shiraz, iran

reza faghihi department of medical radiation and radiation research center, school of mechanical engineering, shiraz university, shiraz, iran

چکیده

introduction radiotherapy planning systems require many percentage depth dose (pdd) and profile measurements and there are various dosimeters that can be used to obtain these scans. as dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (efd) in these fields is of interest. the aim of this work was to investigate the suitability of an unshielded diode for beam scanning in 3×3 cm2, 5×5 cm2, and 10×10 cm2, 6 mv fields. materials and methods an efd was used for all the scans. for comparisons in profile measurements, a tungsten-shielded photon field diode (pfd) was also used. pdds were measured using the pfd and an rk ionization chamber. results very good agreement (0.4%) was found between the pdds measured with efd and pfd for the two larger fields. however, the difference between them exceeded 1.0% slightly for the smallest field, which may be attributed to the effect of the larger pfd perturbation. the rk chamber pdds around 10 cm depth were 1-2% lower than those measured with the diodes. there was good agreement ( conclusion the efd generally agrees well with the pfd and may even perform better in smaller fields.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of an Unshielded Electron Field Diode Dosimeter for Beam Scanning in Small- to Medium-Sized 6 MV Photon Fields

Introduction Radiotherapy planning systems require many percentage depth dose (PDD) and profile measurements and there are various dosimeters that can be used to obtain these scans. As dose perturbation is particularly troublesome in smaller photon fields, using a low-perturbation, unshielded electron field diode (EFD) in these fields is of interest. The aim of this work was to investigate the ...

متن کامل

Monte carlo simulation of varian clinac iX 10 MV photon beam for small field dosimetry

Background: The lack of lateral electronic disequilibrium (LED) becomes a main problem in small field. This factor affects the dose in target volume cannot predict correctly. In addition, utilization of high-energy linear accelerator (10 MV) can emit some unwanted particles (electron contamination). Therefore, the aim of this study was to characterize head linear accelerator (linac) Varian Clin...

متن کامل

Evaluation of MRI-based MAGIC polymer gel dosimeter in small photon fields

Background: Accurate small radiation field dosimetry is essential in modern radiotherapy techniques such as stereotactic radiosurgery (SRS) and intensity modulated radiotherapy (IMRT). Precise measurement of dosimetric parameters such as beam profile, percentage depth doses and output factor of these beams are complicated due to the electron disequilibrium and the steep dose gradients. In the p...

متن کامل

Monte Carlo estimation of electron contamination in a 18 MV clinical photon beam

Background: The electron contamination may reduce or even diminish the skin sparing property of the megavoltage beam. The detailed characteristics of contaminant electrons are presented for different field sizes and cases. Materials and Methods: The Monte Carlo code, MCNPX, has been used to simulate 18 MV photon beam from a Varian Linac-2300 accelerator. All dose measurements were car...

متن کامل

Benchmarking of Monte Carlo model of 6 Mv photon beam produced by Siemens Oncor® linear accelerator: determination of initial electron beam parameters in comparison with measurement

Introduction: The aim of this study was to investigate the initial electron beam parameters for Monte Carlo model of 6MV photon beam produced by Siemens Oncor® linear accelerator.   Materials and Methods: In this study, the EGSnrc Monte Carlo user codes BEAMnrc and DOSXYZnrc were used. The beamnrc code were used for modelling of a 6 MV photon beam produced by...

متن کامل

Estimation of Dosimetric Parameters based on KNR and KNCSF Correction Factors for Small Field Radiation Therapy at 6 and 18 MV Linac Energies using Monte Carlo Simulation Methods

Background: Estimating dosimetric parameters for small fields under non-reference conditions leads to significant errors if done based on conventional protocols used for large fields in reference conditions. Hence, further correction factors have been introduced to take into account the influence of spectral quality changes when various detectors are used in non-reference conditions at differen...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۱۰، شماره ۱، صفحات ۵۱-۵۷

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023