de-noising spect images from a typical collimator using wavelet transform

نویسندگان

farshid babapour mofrad ph.d., candidate, faculty of engineering, science and research branch, islamic azad university, tehran, iran

ali abbaspour tehrani-fard assistant professor, faculty of engineering, science and research branch, islamic azad university, tehran, iran

babak ebrahimi m.sc., faculty of engineering, science and research branch, islamic azad university, tehran, iran

dariush sardari assistant professor, faculty of engineering, science and research branch, islamic azad university, tehran, iran

چکیده

introduction: spect is a diagnostic imaging technique the main disadvantage of which is the existence of poisson noise. so far, different methods have been used by scientists to improve spect images. the wavelet transform is a new method for de-noising which is widely used for noise reduction and quality enhancement of images. the purpose of this paper is evaluation of noise reduction in spect images by wavelet. material and methods: to calculate and simulate noise in images, it is common in nuclear medicine to use monte carlo techniques. the simind software was used to simulate spect images in this research. the simulated and real images formed using the current typical (hexagonal) collimator were de-noised by different types of wavelets. results: the best type of wavelet was selected for spect images. the results demonstrated that the best type of wavelet in the simulated and real images increased signal to noise ratio (snr) by 33% and 45% respectively. also, coefficient of variation (cv) decreased by 77% and 71% respectively, while contrast of recovery (cr) was reduced by only 4% and 9% respectively. conclusion: comparing the results for real spect images in this paper with previously acquired results in real pet images, it can be concluded that the images of both nuclear medicine systems using wavelet transform differ in snr and cr by only 5% and 7% respectively, and in cv by about 20%. therefore, wavelet transform is applicable for nuclear medicine image de-noising.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

De-Noising SPECT Images from a Typical Collimator Using Wavelet Transform

Introduction: SPECT is a diagnostic imaging technique the main disadvantage of which is the existence of Poisson noise. So far, different methods have been used by scientists to improve SPECT images. The Wavelet Transform is a new method for de-noising which is widely used for noise reduction and quality enhancement of images. The purpose of this paper is evaluation of noise reduction in SPECT ...

متن کامل

Image De-noising using Discrete Wavelet transform

The image de-noising naturally corrupted by noise is a classical problem in the field of signal or image processing. Additive random noise can easily be removed using simple threshold methods. De-noising of natural images corrupted by Gaussian noise using wavelet techniques are very effective because of its ability to capture the energy of a signal in few energy transform values. The wavelet de...

متن کامل

Wavelet Transform Based Microarray Image De-noising

Accuracy of microarray gene expression based cancer classification depends on microarray image processing techniques. Image de-noising is one of the crucial step of the microarray image processing. Better the quality of microarray image, more accurate will be the result of cancer classification. In this paper, we have implemented Median filter and wavelet transform based filters with various th...

متن کامل

Wavelet Transform for De - Noising and Enhancement

This paper describes an approach for accomplishing sub-octave wavelet analysis and its discrete implementation for noise reduction and feature enhancement. Sub-octave wavelet transforms allow us to more closely characterize features within distinct frequency bands. By dividing each octave into sub-octave components, we demonstrate a superior ability to capture transient activities in a signal o...

متن کامل

Wavelet Transform in De-noising Geophysical Data

Shallow depth geophysical data from archaeological sites contain various levels and types of noise that hinters the valuable information of the subsurface architectural relics. Wavelet transform techniques were tested as a method for decomposition of the original geophysical data in order to eliminate the noise levels inherent to the geophysical measurements. In addition to the above, unsupervi...

متن کامل

De-noising SPECT/PET Images Using Cross-Scale Regularization

De-noising of SPECT and PET images is a challenging task due to the inherent low signal-to-noise ratio of acquired data. Wavelet based multiscale denoising methods typically apply thresholding operators on sub-band coefficients to eliminate noise components in spatial-frequency space prior to reconstruction. In the case of high noise levels, detailed scales of sub-band images are usually domina...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
iranian journal of medical physics

جلد ۶، شماره Issue ۳,۴، صفحات ۱-۱۲

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023