comparison of subjective refraction, predicted phoropter refraction (ppr) by zywave aberrometer, and final surgical plan used for laser vision correction

نویسندگان

فرید کریمیان

f karimian ophthalmic research center, shahid beheshti university of medical sciences, tehran, iranمرکز تحقیقات چشم- دانشگاه علوم پزشکی شهید بهشتی- تهران- ایران کاملیا شهابی

c shahabi shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی محمدرضا اسدالهی

mr asadollahi shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی مهدی طباطبایی

m tabatabaie shahid beheshti university of medical sciencesدانشگاه علوم پزشکی شهید بهشتی محمد آقازاده امیری

چکیده

purpose: to study the validity and reliability of subjective refraction, predicted phoropter refraction (ppr) measured by zywave aberrometer, and final surgical plan applied for laser vision correction. methods: this prospective study was conducted on 94 myopic or myopic astigmatic eyes (48 patients) who were candidates for refractive surgery in negah eye hospital from april 2012 to july 2012. subjective refraction and ppr by zywave aberrometry were measured and complete ophthalmic examination were performed in all participants. surgical correction of refractive error was then planned, based on the subjective refraction and the patient’s age. the patient underwent customized surface ablation using the bausch & lomb 217 z excimer machine. at 6 months postoperatively, subjective refraction was measured to determine residual refraction. the “exact refraction” was defined as the refraction used for surgery added by postoperative residual refraction. this “exact” amount was compared with the preoperative subjective refraction, ppr and surgical plan. results: the mean difference between “exact” myopia and subjective refraction, ppr, and surgical plan were 0.11±0.51d (p=0.03), 0.18±0.70d (p=0.01), and -0.06±0.46d (p=0.01), respectively. the difference between “exact” myopia and myopia in subjective refraction and ppr was significant. the mean difference between “exact” astigmatism and astigmatism in subjective refraction, ppr and surgical plan were statistically significant (p<0.05). the lowest difference was between “exact” astigmatism and ppr astigmatism. (p=0.021). the correlation coefficient between “exact” myopia and subjective, ppr, and surgical plan myopia were 0.95, 0.92 and 0.96, respectively. also, the correlation coefficient between “exact” astigmatism, subjective, ppr and astigmatism in plan were 0.89, 0.83 and 0.90 respectively. as indicated, the strongest correlation was observed between excat myopia and astigmatism, and prp myopia and astigmatism. conclusion: the mean myopia measured by zywave aberrometer was comparable with exact myopia. planning the myopic refractive correction based on the patient’s subjective refraction and adjusted by age was the most accurate method to achieve the least amount of residual refraction. there was no significant difference between exact astigmatism and preoperative astigmatism measured by the three methods.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of WASCA aberrometer refraction compared to manifest refraction in Chinese adult myopes.

PURPOSE To investigate the accuracy of the Carl Zeiss Meditec Wavefront Supported Custom Ablation (WASCA) aberrometer in refraction testing for Chinese myopic adults. METHODS Manifest refraction and WASCA were performed on 360 eyes of 360 consecutive Chinese myopic adults without cycloplegia. Both vector analysis and conventional notation were applied for comparing results, and differences be...

متن کامل

Comparison between refraction measured by Spot Vision ScreeningTM and subjective clinical refractometry

OBJECTIVE The purpose of this study was to evaluate the accuracy of Spot Vision Screening™ as an autorefractor by comparing refraction measurements to subjective clinical refractometry results in children and adult patients. METHODS One-hundred and thirty-four eyes of 134 patients were submitted to refractometry by Spot and clinical refractometry under cycloplegia. Patients, students, physici...

متن کامل

Wavefront refraction and correction.

Galileo Galilei, the father of experimental science, taught that to understand nature, you must measure nature. Galileo’s contemporary, Christophoro Scheiner, explored the nature of eyes as optical instruments and discovered how to measure the eye’s focusing distance simply by viewing a point of light through closely spaced pinholes in an opaque card. Two centuries later, Thomas Young used Sche...

متن کامل

Radiometric Correction of Anomalous Refraction

We propose a scheme to measure and correct anomalous refraction effects for millimeter wave antennas. A radiometer tuned to the 183 GHz atmospheric water vapor line scans the atmosphere above the aperture of an antenna to determine the spatial derivative of the refractive index. In an array of antennas, such as the MMA, it would be used simultaneously to measure the phase delay correction for t...

متن کامل

The precision of wavefront refraction compared to subjective refraction and autorefraction.

PURPOSE To determine the precision (repeatability) of several methods of calculating refraction from higher-order wavefront aberration data and to compare these wavefront refractions with lower-order (LO) wavefront refraction, subjective refraction, and autorefraction. METHODS Four clinicians refracted 16 normal participants aged 23.6 +/- 1.2 years, 69% female with an average spherical equiva...

متن کامل

Optical Limiting Properties of Colloids Enhanced by Gold Nanoparticles Based on Nonlinear Refraction for Cw Laser Illumination

In this work, thermo-optical properties of gold nanoparticle colloids are studied using continuous wave (CW) laser irradiation at 532 nm. The nanoparticle colloids are fabricated by 18 ns pulsed laser ablation of pure gold plate in the distilled water. The formation of the nanoparticles has been evidenced by optical absorption spectra and transmission electron microscopy. The nonlinear optical ...