assessment of dimensional accuracy of preadjusted metal injection molding (mim) orthodontic brackets

نویسندگان

shiva alavi

farnaz tajmirriahi

چکیده

abstract background: the aim of this study is to evaluate the dimensional accuracy of mbt (mclaughlin, bennett and trevisi ) brackets manufactured by two different companies (american orthodontics and ortho organizers) and determine variations in incorporation of values in relation to tip and torque in these products. methods: in the present analytical/descriptive study, sixty-four maxillary right central brackets manufactured by two companies (american orthodontics and ortho organizers) were selected randomly and evaluated for the accuracy of the values in relation to torque and angulation presented by the manufacturers. they were placed in a video measuring machine using special revolvers under them and were positioned in a manner so that the light beams would be directed on the floor of the slot without the slot walls being seen. then the software program of the same machine was used to determine the values of each bracket type. the means of measurements were determined for each sample and were analyzed with independent t-test and one-sample t-test. results: based on the confidence interval it can be concluded that at 95% probability the means of tip angles of maxillary right central brackets of these two brands were 4.1‒4.3° and the torque angles were 16.39‒16.72°. the tips in these samples were at a range of 3.33‒4.98° and the torque was at a range of 15.22‒18.48°. conclusions:  in the present study, there were no significant differences in the angulation incorporated into the brackets from the two companies; however, they were significantly different from the tip values for the mbt prescription. in relation to torque, there was a significant difference between the american orthodontic brackets exhibited significant differences with the reported 17°, too.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of dimensional accuracy of preadjusted metal injection molding orthodontic brackets

BACKGROUND the aim of this study is to evaluate the dimensional accuracy of McLaughlin, Bennett, and Trevisi (MBT) brackets manufactured by two different companies (American Orthodontics and Ortho Organizers) and determine variations in incorporation of values in relation to tip and torque in these products. MATERIALS AND METHODS In the present analytical/descriptive study, 64 maxillary right...

متن کامل

Development of Metal Plate with Internal Structure Utilizing the Metal Injection Molding (MIM) Process

In this study, we focus on making a double-sided metal plate with an internal structure, such as honeycomb. The stainless steel powder was used in the metal injection molding (MIM) process. The preliminary studies were carried out for the measurement of the viscosity of the stainless steel feedstock and for the prediction of the filling behavior through Computer Aided Engineering (CAE) simulati...

متن کامل

Three-dimensional deformation of orthodontic brackets

Braces are used by orthodontists to correct the misalignment of teeth in the mouth. Archwire rotation is a particular procedure used to correct tooth inclination. Wire rotation can result in deformation to the orthodontic brackets, and an orthodontic torque simulator has been designed to examine this wire-bracket interaction. An optical technique has been employed to measure the deformation due...

متن کامل

Analysis of mesiodistal angulations of preadjusted brackets.

Manufacturers offer various prescriptions of preadjusted brackets for use in the "straight-wire" orthodontic technique. However, the need to incorporate bends in the rectangular wires during orthodontic finishing has led to concerns regarding the type of prescription chosen and the credibility of information provided by the manufacturer. The aim of this study was to compare the slot angulations...

متن کامل

Are torque values of preadjusted brackets precise?

OBJECTIVE The aim of the present study was to verify the torque precision of metallic brackets with MBT prescription using the canine brackets as the representative sample of six commercial brands. MATERIAL AND METHODS Twenty maxillary and 20 mandibular canine brackets of one of the following commercial brands were selected: 3M Unitek, Abzil, American Orthodontics, TP Orthodontics, Morelli an...

متن کامل

Galvanic corrosion of metal injection molded (MIM) and conventional brackets with nickel-titanium and copper-nickel-titanium archwires.

OBJECTIVE To compare the galvanic coupling of conventional and metal injection molded (MIM) brackets with commonly used orthodontic archwires. MATERIALS AND METHODS Six of each type of bracket were suspended in lactic acid along with a sample of orthodontic wire (three nickel-titanium and three copper-nickel-titanium) for 28 days at 37 degrees C. The potential differences between the wires an...