kinetics of pulpal temperature rise during light curing of 6 bonding agents from different generations, using light emitting diode and quartz-tungsten-halogen units: an in-vitro simulation

نویسندگان

najmeh khatoon khaksaran

tahereh jafarzadeh kashi

vahid rakhshan

zahra sadat zeynolabedin

چکیده

background: application of bonding agents (ba) into deep cavities and light curing them might increase pulpal temperature and threaten its health. the purpose of this study was to evaluate temperature rise of pulp by light curing six ba using two different light curing units (lcu), through a dent in wall of 0.5 mm. materials and methods: this in vitro experiment was carried out on 96 slices of the same number of human third molars (6 bas × 2 lcus × 8 specimens in each group). there were 6 groups of bas: n bond, g-bond, optibond xtr, clearfi l se, adper single bond 2 and v bond. each group of ba ( n = 16) had two subgroups of light emitting diode (led) and quartz-tungstenhalogen light cure units ( n = 8). each of these 16 specimens were subjected to light emitting for 20 s, once without any bas (control) and later when a ba was applied to surface of disk. temperature rises in 140 s were evaluated. their mean temperature change in fi rst 20 s were calculated and analyzed using two-way repeated-measures and one-way analysis of variance (anova) and tukey (α = 0.05). furthermore rate of temperature increase was calculated for each material and lcu. results: minimum and maximum temperature rises in all subgroups were 1.7 and 2.8°c, respectively. repeated measures anova showed that both of adhesive and lcu types had signifi cant effect on temperature rise after application of adhesives. tukey post-hoc analysis showed clearfi l se showed signifi cantly higher temperature rise in comparison with adper single bond 2 ( p = 0.047) and n bond ( p = 0.038). temperature rose in a linear fashion during fi rst 30-40 s and after that it was non-linear. conclusion: 20 s of light curing seems safe for pulpal health (with critical threshold of 5.5°c). however, in longer durations and especially when using led units, the process should be broken to two sessions. key words: composite resins, dental materials, differential thermal analysis, polymerization

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative evaluation of the effect of Light Emitting Diode (LED) and Quartz Tungsten Halogen (QTH) light curing units on color stability of Filtek Z350 XT

Introduction:Discoloration of the resin-based composites is a common problem in restorative dentistry. There are many factors associated with the discoloration of dental materials in the oral environment. The purpose of this study was to evaluate the color changes in a nano-composite cured with a quartz-tungsten-halogen (QTH) and light emitting diode (LED) unit. Methods:80 disk-shaped specim...

متن کامل

Shear Bond Strength of Composite to Dentin following Light Curing with Light Emitting Diode and Quartz Tungsten Halogen Light Curing Units

1 Assosiated Professor, Dental Research Center, Dentistry Research Institute, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran 2 Professor, Dental Research Center, Dentistry Research Institute, Department of Restorative Dentistry, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran 3 Research Member, Dental Resear...

متن کامل

Comparison of the bonding strengths of second- and third-generation light-emitting diode light-curing units

OBJECTIVE With the introduction of third-generation light-emitting diodes (LEDs) in dental practice, it is necessary to compare their bracket-bonding effects, safety, and efficacy with those of the second-generation units. METHODS In this study, 80 extracted human premolars were randomly divided into eight groups of 10 samples each. Metal or polycrystalline ceramic brackets were bonded on the...

متن کامل

a comparison of the shear bond strength of orthodontic brackets bonded with light-emitting diode and halogen light-curing units

statement of the problem: various methods such as light emitting diode (led) have been used to enhance the polymerization of resin-based orthodontic adhesives. there is a lack of information on the advantages and disadvantages of different light curing systems. purpose: the aim of this study was to compare the effect of led and halogen light curing systems on the shear bond strength of orthodon...

متن کامل

Light intensity decay in quartz-tungsten-halogen polymerization units.

OBJECTIVES The aim of this study was to determine the effect of ageing on the light intensity of quartz-tungsten-halogen (QTH) polymerization units in dental schools and dental clinics. MATERIALS & METHODS Two dental schools and multiple public health dental clinics were visited and the light intensity of curing units was assessed. The age, make, model and service history were recorded. A cal...

متن کامل

micro-leakage of a fissure sealant cured using quartz-tungsten-halogen and plasma arc light curing units

background and aims. newer curing units such as plasma arc can polymerize the sealants in much shorter curing times. the aim of this study was to compare the effect of two different curing units on the micro-leakage of a fissure sealant material. materials and methods. sixty two extracted premolars without caries were randomly divided into two groups of 31 samples. occlusal surfaces of all teet...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
dental research journal

جلد ۱۲، شماره ۲، صفحات ۰-۰

کلمات کلیدی

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023