the infl uence of thread geometry on biomechanical load transfer to bone: a fi nite element analysis comparing two implant thread designs

نویسندگان

manisha g herekar

viraj n patil

shahnawaz s mulani

megha sethi

چکیده

background: the success of dental implants depends on the manner in which stresses are transferred to the surrounding bone. an important consideration is to design an implant with a geometry that will minimize the peak bone stresses caused by standard loading. the aim of this study was to assess the infl uence of implant thread geometry on biomechanical load transfer and to compare the difference between two different thread designs. materials and methods: a three-dimensional fi nite element model of d2 bone representing mandibular premolar region was constructed. two implants of differing thread geometries, 13-mm length, and 4-mm diameter along with superstructures were simulated. one design featured fourfold microthread of 0.4-mm pitch, 0.25-mm depth in the crestal one-third; 0.8-mm pitch, 0.5-mm depth in the apical two-third. the other design had a single-pitch microthread of 0.8-mm pitch, 0.25-mm depth in the crestal one-third; 0.8-mm pitch, 0.5-mm depth in the apical two-third. a static axial load of 100-n was applied to the occlusal surface of the prosthesis. ansys classic 9.0 (pa,usa) software was used for stress analysis as von mises stresses. results: a comparison of von mises stresses between two thread designs revealed that fourfold microthread allows better stress distribution within the implant body by 43.85%, abutment by 15.68%, its superstructure by 39.70% and 36.30% within cancellous bone as compared to single-pitch microthread. the effective stress transfer to the cortical bone is lowered by 60.47% with single-pitch microthread. conclusion: single-pitch microthread dissipates lesser stresses to cortical bone while the implant body, abutment, and superstructure absorb more stress. this will have a positive infl uence on the boneimplant contact and contribute to preservation of crestal bone. implant with single pitch microthread will thus be preferable to be used in areas where the amount of cortical bone available is less. key words: implant, implant design, microthreads, thread design, thread pitch

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of three different implant thread designs on stress distribution: A three-dimensional finite element analysis

PURPOSE Clinical success of implant prosthodontics is dependent in part upon the type of implant thread design. The selection of implant thread design plays an important role in the outcome of the treatment. This study was undertaken to evaluate the pattern of stress distribution using a finite element analysis; hence, the area which would be bearing maximum load for a given design would be arr...

متن کامل

Comparative study of 12 thread shapes of dental implant designs: a three-dimensional finite element analysis

The purpose of this study was to determine the optimal thread shape for an experimental cylinder implant. Twelve three-dimensional finite element models with an implant of different thread shape were created: 1mm, 2mm, and 3mm square designs (S-1, S-2, and S-3); 90, 60, and 30 V-shaped designs (V-1, V-2, and V-3); 45, 30, and 15 buttress designs (B-1, B-2, and B-3); 45, 30, and 15 reverse buttr...

متن کامل

Thread Thread Thread Thread Thread Thread �

We present the design and implementation of Arachne, a threads system that can be interfaced with a communications library for multi-threaded distributed computations. In particular, Arachne supports thread migration between heterogeneous platforms, with dynamic stack size management and recursive thread functions. Arachne is eecient, exible and portable | it is based entirely on C and C++. To ...

متن کامل

Thread Pitch Variant in Orthodontic Mini-screws: A 3-D Finite Element Analysis

Orthodontic miniscrews are widely used as temporary anchorage devices to facilitate orthodontic movements. Miniscrew loosening is a common problem, which usually occurs during the first two weeks of treatment. Macrodesign can affect the stability of a miniscrew by changing its diameter, length, thread pitch, thread shape, tapering angle and so on. In this study, a 3-D finite element analysis wa...

متن کامل

The influence of thread geometry on implant osseointegration under immediate loading: a literature review

Implant success is achieved by the synergistic combination of numerous biomechanical factors. This report examines the mechanical aspect of implants. In particular, it is focused on macrodesign such as thread shape, pitch, width and depth, and crestal module of implants. This study reviews the literature regarding the effect of implant thread geometry on primary stability and osseointegration u...

متن کامل

Thread A Thread B Thread C

In this paper we classify simultaneous multithreaded architectures based on how they select instructions issued in a single cycle. This classiication allows us to study the present trend of technology as well as to explore the new avenues for improvements in simultaneous multithreaded architectures. Based on our classi-cation, we study the impact of various parameters of simultaneous multithrea...