in vitro study of dentin hypersensitivity treated by 980-nm diode laser

نویسندگان

liu ying nanfang hospital, southern medical university, colleg of stomatology, southern medical university

jie gao department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china.

yan gao center of oral implantology, guangdong provincial stomatological hospital, southern medical university,510280 guangzhou, p.r. china.

shuaimei xu department of stomatology, nanfang hospital, colleg of stomatology, southern medical university,510515 guangzhou, p.r. china.

چکیده

introduction: to investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (dh). methods: twenty extracted human third molars were selected to prepare dentin discs. each dentin disc was divided into four areas and was irradiated by 980-nm diode laser under different parameters: group a: control group, 0 j/cm²; group b: 2 w/cw (continuous mode), 166 j/cm²; group c: 3w/cw, 250 j/cm²; and group d: 4w/cw, 333 j/cm². ten additional extracted human third molars were selected to prepare dentin discs. each dentin disc was divided into two areas and was irradiated by 980-nm diode laser: group e: control group, 0 j/cm²; and group f: 2.0 w/cw, 166 j/cm². the morphological alterations of the dentin surfaces and odontoblasts were examined with scanning electron microscopy (sem), and the morphological alterations of the dental pulp tissue irradiated by laser were observed with an upright microscope. results: the study demonstrated that dentinal tubules can be entirely blocked after irradiation by 980-nm diode laser, regardless of the parameter setting. diode laser with settings of 2.0 w and 980-nm sealed exposed dentin tubules effectively, and no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. conclusions: irradiation with 980-nm diode laser could be effective for routine clinical treatment of dh, and 2.0w/cw (166 j/cm²) was a suitable energy parameter due to its rapid sealing of the exposed dentin tubules and its safety to the odontoblasts and pulp tissue.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Vitro Study of Dentin Hypersensitivity Treated by 980-nm Diode Laser.

INTRODUCTION To investigate the ultrastructural changes of dentin irradiated with 980-nm diode laser under different parameters and to observe the morphological alterations of odontoblasts and pulp tissue to determine the safety parameters of 980-nm diode laser in the treatment of dentin hypersensitivity (DH). METHODS Twenty extracted human third molars were selected to prepare dentin discs. ...

متن کامل

Microhardness of radicular dentin treated with 980-nm diode laser and different irrigant solutions.

OBJECTIVE The aim of this study was to evaluate the microhardness of radicular dentin after treatment with 980-nm diode laser and different irrigant solutions. BACKGROUND DATA There are few reports of the consequences of diode laser irradiation emitted at 980 nm on the mechanical properties of dentin. METHODS Seventy-two single canal, human canines with complete root formation were randomly...

متن کامل

Human Skin Wound Welding Using 980 nm Diode Laser: an in Vitro Experimental Study

Laser assisted skin wound closure offers many distinct advantages over conventional closure techniques. The objective of this in vitro experimental study, carried out at the Institute of Laser for Postgraduate Studies/Baghdad University, was to determine the effectiveness of 980 nm diode laser in welding of human skin wounds. Multiple 3-4 cm long full thickness incisions in a specimen of human ...

متن کامل

Laser lipolysis with a 980 nm diode laser.

Laser lipolysis is recognized as an effective, non-surgical solution for fat removal and body reshaping. Its appeal lay in the procedure's ability to treat localized fat deposits and correct body asymmetries with apparent decreased risk compared to traditional liposuction. The energy emitted by the laser uses volumetric heating to destroy fat cells, contract skin and stimulate collagenesis. Alt...

متن کامل

Apical microleakage and SEM analysis of dentin surface after 980 nm diode laser irradiation.

This study evaluated the effect of 980-nm diode laser on apical microleakage and intraradicular dentin morphology. Roots of 110 mandibular incisors were used in the study: 92 for microleakage test and 18 for scanning electron microscopy (SEM). Roots were randomly assigned to 3 groups according to the irrigating solution (water, NaOCl and NaOCl/EDTA) and were divided into 3 subgroups according t...

متن کامل

Histologic evaluation of laser lipolysis: pulsed 1064-nm Nd:YAG laser versus cw 980-nm diode laser.

BACKGROUND The use of the laser as an auxiliary tool has refined the traditional technique for lipoplasty. During laser lipolysis, the interaction between the laser and the fat produced direct cellular destruction before the suction, reduced bleeding, and promoted skin tightening. OBJECTIVE This study sought to perform a comparative histologic evaluation of laser lipolysis with the pulsed 106...

متن کامل

منابع من

با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید


عنوان ژورنال:
journal of lasers in medical sciences

جلد ۴، شماره ۳، صفحات ۱۱۱-۱۱۹

میزبانی شده توسط پلتفرم ابری doprax.com

copyright © 2015-2023